American Megatrends MegaRAID Express 500 Manuale Utente

Pagina di 118
Chapter 5 Configuring MegaRAID Express 500
45
Configuration Strategies
The most important factors in RAID array configuration are: drive capacity,
drive availability (fault tolerance), and drive performance. You cannot configure
a logical drive that optimizes all three factors, but it is easy to choose a logical
drive configuration that maximizes one factor at the expense of the other two
factors, although needs are seldom that simple.
Maximize Capacity RAID 0 achieves maximum drive capacity, but does not provide data
redundancy. Maximum drive capacity for each RAID level is shown below.
OEM level firmware that can span up to 4 logical drives is assumed.
RAID
Level
Description
Drives
Required
Capacity
0
Striping
without parity
1 – 32
(Number of disks) X capacity of
smallest disk
1
Mirroring
2
(Capacity of smallest disk) X (1)
3
Striping with
fixed parity
drive
3 – 8
(Number of disks) X (capacity of
smallest disk) - (capacity of 1 disk)
5
Striping with
floating parity
drive
3 – 8
(Number of disks) X (capacity of
smallest disk) - (capacity of 1 disk)
10
Mirroring and
Striping
4 – 8 (Must
be a multiple
of 2)
(Number of disks) X (capacity of
smallest disk) / (2)
30
RAID 3 and
Striping
6 – 32 (Must
be a multiple
of arrays)
(Number of disks) X (capacity of
smallest disk) – (capacity of 1 disk X
number of Arrays)
50
RAID 5 and
Striping
6 – 32 (Must
be a multiple
of arrays)
(Number of disks) X (capacity of
smallest disk) – (capacity of 1 disk X
number of Arrays)
Note:
The maximum number of physical drives supported per controller is 15.
Cont’d