5. USING THE OPERATION PANEL (BASIC OPERATIONS) 
 
 
29 
BAS-300G, BAS-311G, BAS-326G 
5-4. Setting the X-scale and Y-scale 
The scales are set to 100 (%) at the time of shipment from 
the factory. 
1. Press the SELECT key (1) so that the X-SCALE 
indicator (2) (for X-scale setting) or the Y-SCALE 
indicator (3) (for Y-scale setting) is illuminated. 
•  The setting value (%) will appear in the menu display 
(4). 
*  When memory switch no. 402 is set to "ON", the 
settings will be displayed in units of mm. 
2. Press the   or    key (5) to set the scale (0 
− 400). 
•  The program number will flash in the PROGRAM No. 
display (6). 
3.  Depress the foot switch to the 2nd step. 
(If using a two-pedal foot switch, lower the work clamp 
before depressing the start switch.) 
•  The feed mechanism will move to the home position 
and the scale will be accepted. 
•  The program number will stop flashing and illuminate 
steadily. 
NOTE: 
After completing the setting, be sure to refer to "5-6. 
Checking the sewing pattern" to check that the needle 
drop position is correct. 
 
 
 
5-5. Setting the sewing speed 
The sewing speed is set to 2000 (sti/min) at the time of 
shipment from the factory. 
1.  Press the SELECT key (1) until the SPEED indicator (2) 
illuminates. 
•  The setting value (sti/min) will appear in the menu 
display (3). 
2. Press the   or    key (4) to set the sewing speed. 
(Sewing speed setting: 400 
− 2700) 
 
 
 
 
 
4955Q
2nd step 
4956Q