Braun Mobility Aid RA200 Manuale Utente

Pagina di 40
Page 21
Torn or detached tape   
 
Proper floor level height  
Proper floor level rotation 
Proper stow level
Proper floor threshold alignment
Excessive wear
Loose rivet
Proper closure
Excessive interference during
   stowing cycles
Debris buildup
Pin fatigue
Spring fatigue/failure
Debris build up
Damage, fatigue & adhesion
Excessive wear
Uncharacteristic marks
Debris buildup
Pin fatigue
Debris buildup
Positive lock engagement
Replace tape 
 
Floor height per ramp support 
Floor level sensor pick-up
Stow level sensor pick-up
Carriage “full out” alignment
Replace pad
Replace rivet, pad
Inspect front cover hinge (next item)
Check platform position for 
   clearance.
See Troubleshooting Guide
Clean, lubricate
Replace hinge
Replace hinge
Clean
Replace seals
Replace pads   
Identify marking item and correct
Clean, lubricate
Replace
Clean 
Re-engage
15
13, 14
13, 14
20
12
13
24, 25
12, 13
 
 
 
13
13
12
12
Below is a list of routine inspections which should 
be done to ensure optimal ramp performance and 
prevent excessive wear leading to poor operation 
and possible component failure.  Refer to the speci-
fied pages within this manual for further details.  
These ramp inspections should be performed if the 
ramp has unusual malfunctions, the bus is undergo-
ing routine service, or after every 500 completed 
cycles, whichever comes first.  If the ramp fails to 
operate at a satisfactory level after performing these 
inspections and the accompanying adjustment or 
course of action, please contact your local Braun 
distributor or The Braun Corporation’s Product Sup-
port Department for further assistance.
 
 
 
 
See Manual
 
Inspect 
For What 
Action/Adjustment 
Page No.
  Exterior Inspection
Platform
Ramp
 Skid Pads
Front
Cover
Front
Cover
 Hinge
Front
Cover
Seals
Front
Cover
Skid pads
Ramp Hinge
Electrical
Connectors
Inspection List