Maytag CANYON C310 Manuale Utente

Pagina di 16
8
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
c
himney
 r
equiremenTs
The Canyon™ C310 inserts are approved for use in masonry 
fireplaces built to UBC Chapter 37 or equivalent with a mini-
mum 30” opening at the front of the fireplace.
Do not remove brick or mortar from masonry fireplace to 
accommodate insert. Do not remove brick or mortar from 
masonry fireplace to accommodate insert.  Approved with or 
without positive flue connection.  Approved with minimum 
6” (152mm) diameter stainless steel listed reline system.  
Ask your dealer for recommended chimney size. Country 
Collection inserts are tested to  UL 1482 / ULC S628-93 and 
listed by OMNI-Test Laboratories, Inc.; Beaverton, OR.
Remove and clean behind unit frequently, as creosote build 
up may occur rapidly.
i
nsTallaTion
 P
roceDures
 - m
asonry
 c
himney
NOTE:  Although not required, a full-length stainless steel liner is 
recommended for optimum safety and performance.  See your 
Lennox Hearth Products dealer for details.
Note:  When installing your stove with a positive flue connection, 
be sure to leave the insulation off the surround panels (flanges) and 
leave  a 1/4” (6mm) airspace insulation off the surround panels 
and the facing of your fireplace.
1. READ ENTIRE INSTALLATION INSTRUCTIONS.
2. Check all REQUIRED CLEARANCES as specified in the previous 
section (page 7) of this installation instruction booklet.
3. Wear gloves during installation in case of sharp edges on the 
stove and it’s parts
4. Determine the depth of the fireplace lintel.  The lintel is the 
masonry area over the fireplace opening, and is supported by 
a noncombustible plate, usually of steel.  The depth may vary 
from a single brick width (4”/102mm) to that of several brick.  
If any portion of the flue collar opening on top of the insert (as 
shown in the diagram below) will project under the lintel area, 
a deflector plate must be mechanically attached to the fireplace 
insert to divert heat and gases away from the lintel.  Consult your 
dealer for the correct attachment piece.  Compare lintel depth 
to the distance from the flue collar opening to the fireplace to 
determine if this caution pertains to your installation.  If there 
is sufficient clearance, a flue offset may also be used.  Consult 
your dealer. 
5. Open or remove the existing fireplace damper.  Make sure the 
damper cannot fall closed.
6. Install the two 1/2” x 3” (13mm x 76mm) leveling bolts -heads 
up- a few turns in the leveling nuts on each side of the outer 
chamber of the insert at the lower rear corners.
7. Position the insert in the center of the fireplace opening and 
push it back until the surround brackets are approximately 2” 
(51mm) away from the fireplace front.
8. Install the side surround panels and push the insert up snug 
against the fireplace face.  Then with the location selected re-
move the surround panels and level the stove with the leveling 
bolts using a 3/4” (19mm) socket, extensions (to reach the bolt 
head), and a ratchet.
9. Glue the insulation around the outer edge of both the top and 
side surround panels.
10.  Install the surround panels loosely, align and tighten.  Check 
for a tight fit against the fireplace.
11. Install the brick and baffle as per instructions on page 6.
POSITIVE FLUE CONNECTION: See your authorized Len-
nox Hearth Products dealer for necessary accessories and 
installation instructions.
Positive flue connectors required for installation in Canada are 
available from your Lennox Hearth Products dealer. Please 
use one the part numbers indicated below.
7112 - 8" Positive Flue Connector Ring Kit
711 - 8" to " Reducer w/ Positive Flue Connector
Lintel
Flue Outlet
Not to Scale
Brick Face
Insert Surround
Smoke 
Deflector
Mechanically
Attached to
Insert
Figure