To delete a user ID using the record number, specify the number as a qualifier after the 
DELETEUSER
 command in the form DELETEUSER /N, where N is the user record 
number. 
 
6.3 
Devices
Devices
Devices
Devices Command 
 
Device port parameters must be defined by the sys admin using the DEVICES 
command.  If a single device port is to be changed, the port number must follow the 
DEVICES
 command.  If the DEVICES command is entered by itself, the configuration of 
all device ports will be listed.  To edit all possible device ports for a unit, enter the 
command DEVICES /ALL. 
 
Programmable elements include: device name, baud rate, stop bits, parity, data bits, 
DCE/DTE, flow control and inhibit direct mode.  Pressing <ENTER> accepts the 
parameter as is.  If changes need to be made, each parameter may be edited as it 
comes up after each > prompt. 
 
The device name may not contain the * character.  If a name is entered with this 
character, the administrator will be asked to re-enter the name. 
 
Four baud rates are offered: 9600, 19200, 38400, and 57600.  Most devices use 9600 
as the console/admin port baud rate, so the device port defaults to this value.  Check 
the equipment documentation for the proper baud rate. 
 
The format of the bit-wise transmission of data is determined by the stop bits, parity, 
and data bits parameters.  The default settings are 1 stop bit, no parity, and 8 data bits.  
Check the equipment documentation for the proper settings. 
 
Each device port may be separately configured as either DCE or DTE.  The DCE setting 
is used when connecting to a DTE device such as a computer.  The DTE setting is used 
when connecting to a DCE device such as a managed switch.  The device ports are 
configured as DCE by default. 
 
The device port flow control setting determines the method of flow control.  The two 
most common settings are XON/XOFF (a.k.a. software) and RTS/CTS (a.k.a. 
hardware).  DTR/DSR is used very infrequently.  The default setting for the device ports 
is XON/XOFF.  Check the equipment documentation for the correct flow control setting. 
 
The INHIBIT DIRECT MODE setting allows the administrator to turn off port buffering 
while a user is connected to the device and is in direct mode.  The device port buffer still 
collects data while not in direct mode when this setting is active.  It may be desirable to 
disable direct mode buffering so sensitive data is not viewable by other users, but alert 
and panic messages from the attached device are still stored when nobody is 
connected.  This setting is disabled by default, so buffer data is collected both in and out 
of direct mode.