Hotpoint HTDP120EDWW Foglio Delle Specifiche

Pagina di 3
Listed by 
Underwriters 
Laboratories
Dryer Exhausting Information   – Use Metal Duct Only 
Vertical and Horizontal Ducting
  
90 ft. 
60 ft.
  
60 ft. 
45 ft.
6.8 and 5.8 cu. ft.  
45 ft. 
35 ft.
Capacity Models 
35 ft. 
25 ft.
all Electric Dryers 
25 ft. 
15 ft.
  
90 ft. 
60 ft.
6.8 and 5.8 cu. ft. 
60 ft. 
45 ft.
Capacity Models 
45 ft. 
35 ft. 
all Gas Dryers  
30 ft. 
25 ft.
Portable/Stationary Models 
     DSKS433EB 
46 ft. 
37 ft.
     DSKS333EC 
38 ft. 
30 ft. 
     DSKP333EC 
31 ft. 
22 ft. 
     WSM2780H 
24 ft. 
15 ft.
  
56 ft. 
42 ft.
  
46 ft. 
36 ft.
Unitized Model 
34 ft. 
28 ft.
     WSM2700H 
32 ft. 
18 ft.
Unitized Models 
43 ft. 
36 ft.
     WSM2420D 
33 ft. 
26 ft.
     WSM2480D 
23 ft. 
16 ft.
Number
of
90°
Turns
Maximum Length of  
4"-Dia. Rigid Metal Duct 
Exhaust Hood Type
Domestic  
Dryer Models
A
4" Opening
B
2-1/2" 
Opening
Best Performance
B
2-1/2
4
A
A
For complete information, see installation instructions packed with your dryer.
Ducting Materials: 
For best performance, this dryer should be vented with 4" diameter all rigid metal exhaust duct. 
If rigid metal duct cannot be used, then UL-listed flexible metal (semi-rigid) ducting can be used 
(Kit WX08X10077). In special installations, it may be necessary to connect the dryer to the 
house vent using a flexible metal (foil-type) duct. A UL-listed flexible metal (foil-type) duct may 
be used ONLY in installations where rigid metal or flexible metal (semi-rigid) ducting cannot be 
used AND where a 4” diameter can be maintained throughout the entire length of the transition 
duct. Please see installation instruction packed with your dryer for complete instructions when 
using flexible metal (foil type) ducting. 
Exhaust Length Calculation: 
1.  Determine the number of 90° turns needed for your installation. If you exhaust to the side or 
bottom of dryer, add one turn.
2.  The maximum length of 4' rigid (aluminum or galvanized) duct which can be tolerated is 
shown in the table.
   A turn of 45° or less may be ignored. Two 45° turns within the duct length should be treated 
as a 90° elbow. A turn over 45° should be treated as a 90° elbow.
Dryers must be exhausted to the outside.
Caution: For personal safety do not terminate exhaust into a chimney, under any enclosed 
house floor (crawl space), or into an attic, since the accumulated lint could create a fire hazard or 
moisture could cause damage. Never terminate the exhaust into a common duct or plenum with 
a kitchen exhaust, since the combination of lint and grease could create a fire hazard.
Exhaust ducts should be terminated in a dampered wall cap to prevent back drafts, bird nesting, 
etc. The wall cap must also be located at least 12" above the ground or any other obstruction 
with the opening pointed down.
HTDP120ED – Hotpoint
®
 6.8 cu. ft. capacity DuraDrum
 electric dryer
Specification Created 1/12
470164