Installation
 
3
A
B
C
D
E
F
G
H
J
K
L
M
N
p
Q
R
mm 1478
948
910
680
1388
756
1145
698
116
10
565
689
43
118
55
634
ins
58 ¼
37 
�/8
35 
26 
¾
54 
29 
¾
45 
27 
½
�/8 22¼ 27⅛ 1¾ 4⅝ 2⅛
25
Range Dimensions 
When surveying for a range installation the actual clearance required 
for the ‘body’ of the appliance should be increased by ⅜" beyond the 
figures quoted above. This allows safe margin to take into account the 
natural dimensional variations found in major castings. In particular the 
width across the appliance recess could be critical.
Range Base or Hearth 
It is essential that the base or hearth on which the range stands should 
be level and be capable of supporting the total weight of the range. The 
base of the built-in AGA plinth must be level and sit above the finished 
height for service access.
Plinth
The front plinth cover is removable and must not be obstructed by 
flooring or tiles. If necessary the range must be raised by the thickness of 
the tiles to ensure the plinth can be removed.
Rear Wall
The wall behind the range must be of non-combustible material with a 
minimum thickness of 1” (25mm).
Minimum Clearances to Combustibles
A gap of at least 1/2” must be observed between the rear of the top 
plate, and the wall behind the range. If the rear wall is of combustible 
material there must be a gap of 1 1/2” (38mm).
NATURAL GAS
MAXIMUM HEAT 
INPUT
6,800 Btu/hr
Thermostat Bypass
70
Main Burner Injector
112
Gas Supervision 
Injector
4212
Inlet Pressure
8” w.g.
Burner Pressure
4” w.g. 
Specifications are subject to change without notice.  Visit www.aga-ranges.com for the most up-to-date information.
Side Clearances
A ⅛" (3mm) gap is required each side between the range 
top plate and adjoining work surfaces that may be fitted, 
this is to allow for the safe removal of the top plate should 
this be required at a later date.
Where ranges are to be fitted against a side wall a 4 ⅝" 
(116mm) clearance is required on the right and left hand 
side for
oven door access. If the AGA is to be installed in a brick 
recess, then the minimum clearance should be increased 
by at least ⅜" (10mm), to allow for the walls not being 
square.
In addition a minimum clearance of 39 ⅜" (1000mm) must 
be available at the front of the range to enable the range 
to beserviced.