STEP 1 
STEP 2 
STEP 3 
STEP 1
STEP 4 
STEP 2
STEP 3
STEP 4
NOTICE
SLEEVE  projections  and  leveling  precautions 
must  be  observed  to  prevent  the  entry  of 
water into the room. 
WSE
B
61603304 
OUTDOOR WEATHER PANEL (PAINTED METAL) 
61603012
ASSY  GRILLE WSE SLEEVE
61578101 
GASKET (ATTACHED TO SLEEVE) 
The WSE  SLEEVE should be positioned so that the 
DRAIN EXTENSION extends a minimum of 9/16”
 
beyond the OUTSIDE WALL. (See Figure
 5)
The WSE  SLEEVE must extend a minimum of 7/8” 
beyond the INSIDE WALL. 
The WSE  SLEEVE must be installed level side to side.
The WSE SLEEVE must also be installed with a 
downward tilt toward the outside of the building. If a 
level is placed so that it rests on the FRONT and BACK 
UNIT REST as shown in Figure
 6, a properly installed 
unit provides a 3/8” slope to the outside of the building
After unpacking the WSE  SLEEVE from the carton, 
remove the 
INDOOR WEATHER PANEL. Place 
the WSE SLEEVE in the wall opening following the 
instructions given in the INSTALLATION 
REQUIREMENTS. Attach the SLEEVE to the INSIDE 
WALL by driving two #12A x 2” screws in each side of 
the SLEEVE
. (see Figure 5) Shim at the top of the 
SLEEVE, midway between the sides. Drive one #12A 
x 2” screw in the top of the SLEEVE. If the wall opening 
is not framed with wood, use expansion anchor bolts 
or molly (toggle) bolts (not provided).
Once the SLEEVE has been installed, check the LEVEL 
again  to  be  sure  the  3/8”  downward  slope  is 
maintained.
NOTE: If necessary, apply shims below the chassis 
and inside the sleeve FRONT 
UNIT  REST, to ensure 
a 3/8” downward slope front to back.
Caulk the perimeter of the entire opening on the 
inside and the outside between the SLEEVE and the 
WALL.
The  indoor  weather  panel  removed  in  Step  1  above 
must be remounted back in place if masonry work is
 
to be done and/or if the “WallMaster”chassis is to be 
installed at a later date.
A
SLEEVE
SHIM TO 
PROPER 
 SPA CING
FRONT UNIT REST
LEVEL
BACK UNIT REST
CAULK
(AS NEEDED)
CAULK 
(AS NEEDED)
CAULK 
(AS NEEDED)
BACK OF UNIT
FRONT OF UNIT
3/8 SLOPE
FIGURE
 
6
61603200
IN
DOOR WEATHER PANEL (METAL)
Sleeve Installation
Installation Requirements
How to cover inner weather panel holes
Two beige plugs are included in the plastic bag 
taped to the WallMaster chassis. These plugs may be 
used to cover the two holes left after removing the 
i
ndoor weather panel.