STANDARD FEATURES
CABINET
The AirBoss Series cabinet is constructed of 18 gauge steel with a gray polyester powder
coated finish that will compliment any decor. The entire cabinet is insulated with a sound-
absorbing insulation for cool, quiet comfort. All units come equipped with handles and
swivel casters for portability and convenient set-up.
ELECTRONIC THERMOSTAT
coated finish that will compliment any decor. The entire cabinet is insulated with a sound-
absorbing insulation for cool, quiet comfort. All units come equipped with handles and
swivel casters for portability and convenient set-up.
ELECTRONIC THERMOSTAT
All Air Boss unit are equipped with a non-programmable electronic thermostat. When
power is connected to the unit, the thermostat will control the Air Boss to cool a space to
the desired temperature. The thermostat is also capable of controlling the fan to operate
automatically (when needed) or continuously. To protect the compressor from short-
cycling, there is a built-in, 4-minute time delay in the thermostat.
FAN SPEED CONTROL
power is connected to the unit, the thermostat will control the Air Boss to cool a space to
the desired temperature. The thermostat is also capable of controlling the fan to operate
automatically (when needed) or continuously. To protect the compressor from short-
cycling, there is a built-in, 4-minute time delay in the thermostat.
FAN SPEED CONTROL
A two position rocker switch, located next to the thermostat, provides the user with the
option of running the evaporator fan in high-speed or low-speed.
CONDENSATE RESERVOIR/PUMP
option of running the evaporator fan in high-speed or low-speed.
CONDENSATE RESERVOIR/PUMP
Air Boss units come equipped with a means for handling the condensate generated dur-
ing the cooling process. All models except the 5-ton models come equipped with a
Condensate Reservoir Tank, that captures the condensate from cooling. The tank can
then be easily removed from the unit and emptied as required.
ing the cooling process. All models except the 5-ton models come equipped with a
Condensate Reservoir Tank, that captures the condensate from cooling. The tank can
then be easily removed from the unit and emptied as required.
The 5-ton Air Boss models come equipped with an Automatic Condensate Pump that
disposes of the condensate. The pump comes with a 25 foot long vinyl hose that allows
for the disposal of the condensate water to a drain. The automatic pump is capable of a
20ft lift, to handle just about any installation requirement.
CONDENSATE ALARM LIGHT
disposes of the condensate. The pump comes with a 25 foot long vinyl hose that allows
for the disposal of the condensate water to a drain. The automatic pump is capable of a
20ft lift, to handle just about any installation requirement.
CONDENSATE ALARM LIGHT
On the front of all Air Boss models, there is a Condensate Alarm Light (RED) located near
the thermostat. For models less than 5-tons, the light indicates that the condensate tank
is full and needs to be emptied. In the 5-ton Air Boss units (model PAC60) the light indi-
cates a condensate pump over-flow condition where the pump is either disabled, or inca-
pable of rejecting the condensate water, and must be serviced.
FILTERS
the thermostat. For models less than 5-tons, the light indicates that the condensate tank
is full and needs to be emptied. In the 5-ton Air Boss units (model PAC60) the light indi-
cates a condensate pump over-flow condition where the pump is either disabled, or inca-
pable of rejecting the condensate water, and must be serviced.
FILTERS
All Air Boss units are equipped with washable filters at the air intakes. 1/8” mesh air filters
located behind the evaporator return air grill serve to filter the air before it is cooled. A
1/2” aluminum mesh filter serves to protect the condenser coil from dust build-up. Both
filters can be easily removed and cleaned.
HIGH PRESSURE SAFETY SWITCH
located behind the evaporator return air grill serve to filter the air before it is cooled. A
1/2” aluminum mesh filter serves to protect the condenser coil from dust build-up. Both
filters can be easily removed and cleaned.
HIGH PRESSURE SAFETY SWITCH
Located on the back of the Air Boss unit is a manual re-set high pressure switch, used for
the protection of the compressor. If the condensing pressure exceeds the limit setting, the
cut-out shuts down the compressor, while the evaporator fan remains running. The com-
pressor can be re-started, once the condensing pressure has lowered, by depressing the
“RESET” button.
POWER CORDS
the protection of the compressor. If the condensing pressure exceeds the limit setting, the
cut-out shuts down the compressor, while the evaporator fan remains running. The com-
pressor can be re-started, once the condensing pressure has lowered, by depressing the
“RESET” button.
POWER CORDS
All Air boss units come with power cords, convenient connection and portability. All units
except the 5-ton models, and 3-phase models are equipped with LCDI for added safety
devices.
except the 5-ton models, and 3-phase models are equipped with LCDI for added safety