Fantec TC-400R2U 1562 Manuale Utente

Codici prodotto
1562
Pagina di 3
 I-Star Computor Co., Ltd                     TC-400R2U      400W  2U redundant 
               
                                                                                     
 
Professional Power supply …… Industrial PC, Server, Storage 
Best Solution Guide 
                                                                AC Input: 
                                                           
VOLTAGE:100~240V(Active PFC/Full Range) 
FREQUENCY:47~63Hz 
POWER FACTOR CORRECTION:0.95 
INPUT CURRENT:8A/4A For 115/230VAC 
INRUSH CURRENT:60A/80A MAX FOR 115/230
 
DC Output 
OUTPUT CURRENT 
REGULATION 
OUTPUT 
OUTPUT 
VOLTAGE 
MIN(A) 
MAX(A) 
LOAD 
LINE 
RIPPLE & NOISE 
MAX.[P-P] 
+5V 3 40 
±5% 
±1% 50mV 
+12V 
28 
±5% 
±1% 
120mV 
-5V 
0.1 
0.5 
±10% 
±1% 
150mV 
-12V 
0.1 
0.8 
±10% 
±1% 
150mV 
+3.3V 
1 20 
±5% 
±1% 50mV 
+5VSB 
0.1 
±5% 
±1% 
50mV 
The combined output power +5V&+3.3V shall not exceed 40A. 
The total power shall not exceed 400W. 
 
Features… 
  TEMPERATURE RANGE:Operation 0℃~50
 
℃  
  HOLD UP TIME:16ms at maximum load & normal input voltage 
  EFFICIENCY:70% TYPICAL(Normal Line) 
  POWER GOOD SIGNAL:Should be asserted high to indicate that+5VDC and +3.3VDC 
output are above the low voltage thresholds. Compatible signal out with 100ms to 500ms. 
  OVER POWER PROTECTION:The power supply shall shout down output power   
exceeds 130% to 160%   
  OVER VOLTAGE PROTECTION:+5V, +3.3V and +12V DC outputs set at 110%-130%   
    SHORT CIRCUIT PROTECTION:A short circuit placed between the DC return and 
the output shall cause no damage and the power supply shall shutdown. 
  EMI:FCC part 15, subpart B, Class B, EN55022 CISPR22 Class B. 
◎    Meet EN-61000-3-2 CLASS D ( Active PFC )
 
  GAENCY APPROVALS:UL60950, CAN/CSA22.2 No.60950, TUV(IEC60950) 
    MTBF OF POWER SUPPLY ELECTRONNIS:100,000 hours at 25℃. 
LIFE EXPCTANCY OF FAN 40,000 hours at 40℃ 
  COLLING:By forced air 1x40mm Fan (Each module) 
  DIMENSION:D280 X W101 X H84mm