Countertop Requirements
9
WARNING
To reduce the risk of ignition of surrounding 
combustible materials, install at least 12" 
(300 mm) from both sidewalls and at least 2" 
(50 mm) from the rear wall.
The countertop must be level and horizontal. The 
stability of the countertop must be maintained after 
the cut-out has been made.
Solid surface countertops often require special 
installations. For example, heat-reflective tape and 
rounded corners may be necessary. Contact the 
countertop manufacturer for instructions specific to 
your countertop.
Technical Data
Prepare Installation Space
The kitchen unit must be heat-resistant to at least 
200° F (90°C). The stability of the unit must be 
maintained after producing the cut-out.
Produce the cut-out in the countertop for one or more 
Vario appliances as shown in the installation sketch. 
The angle between the cut surface and the countertop 
must be 90°.
The cut edges at the sides must be flat to ensure a 
good fit of the retaining springs on the appliance. In 
laminated worktops, it may be necessary to fit strips at 
the sides of the cut-out.
Remove shavings after cutting. Seal cut surfaces for 
resistance to heat and so they are watertight.
Pay attention to a minimum gap of 3/8“ (10 mm) from 
the underside of the appliance to kitchen units.
Use suitable base constructions to ensure load-
carrying capacity and stability, especially in the case 
of thin countertops. Pay attention to the weight of the 
appliance, including any payload. Reinforcement 
material used must be resistant to heat and moisture.
Note:  Wait until the appliance has been installed in 
the installation opening before checking that it is 
level.
Cutting out countertop
D
minimum 4" (102 mm)
for non-combustible back-walls the 
minimum distance can be reduced to 1
9
/
16
(40 mm)
E
minimum 36" (914 mm)
F
minimum 18" (457 mm)
G
maximum 13" (330 mm)
Total connected load electric
15 VA
Total connected load gas (natural 
gas)
59,700 BTU/h 
(17.5 kW)
Total consumption  
(natural gas)
1.6 m³/h
Total connected load gas 
(propane gas)
58,000 BTU/h 
(17.0 kW)
Total consumption  
(propane gas)
1,210 g/h




PLQ

PLQ
PLQ


PLQ




“




“


  PP



“

“