Marvel M24DZBGPL Istruzione Sull'Installazione

Pagina di 56
11
INSTALLING THE CABINET
Anti - tip Bracket considerations
Before placing the cabinet in opening, the depth of the 
cut-out opening should be at least 24" (61cm). If the cut-out 
opening depth is more than 24" (61cm), then a piece of 
wood must be secured crosswise on the wall into the studs 
at the height of the anti-tip brackets. (See Figure 8). Slide 
the cabinet into position and level the cabinet with adjust-
able rear roller and front leveling legs. (See Leveling the 
unit on page 12). 
The anti tip bracket is fastened to the cabinet and runs the 
full width of the cabinet. Locate a wall stud behind the cabi-
net and secure the anti-tip bracket with at least (2) #8 x 1
1
2
” 
screws provided. See Figure 7.
-Wall stud
-Anti-tip
bracket 
on top of 
cabinet
-At least 2 
screws into 
wall stud.
Figure 7
-Crosswise
lumber