Elica ECM6XS2 Istruzione Sull'Installazione

Pagina di 21
 
12 
 
Installation - Ductless (Recirculating) version 
  
CAUTION 
To install the hood in this version, first purchase the 
Ductless Recirculating Kit. 
includes: charcoal filter and deflector 
  
  If possible, disconnect and move freestanding or slide-in 
range from cabinet opening to provide easier access to 
rear wall. Otherwise put a thick, protective covering over 
countertop, cooktop or range to protect from damage 
and debris. Select a flat surface for assembling the unit. 
Cover that surface with a protective covering and place 
all canopy hood parts and hardware in it. 
 
   Determine and mark the centerline on the wall where the 
canopy hood will be installed. 
 
   Select a mounting height comfortable for the user and 
mark on wall. 
 
   Tape template, matching center-line and hood bottom. 
Mounting the duct cover bracket 
The  duct  bracket  should  be  installed  against  the  back  wall 
and flush with the ceiling. 
This  bracket  will  hold  the  telescopic  duct  cover  in  place  at 
the top. 
 
Secure the bracket to the wall: 
•  Align  the  marked  centerline  on  the  bracket  with  the 
centerline on the wall. 
•  Mark 2 screw hole locations in the wall. 
•  Drill 5/16" pilot holes in the marked locations. 
•  Install wall fastener anchors. 
•  Drive  wood  screws,  by  hand,  into  the  fastener  to  allow 
anchors to expand. Remove the screws. 
•  Secure the bracket to the wall with wood screws and/or 
fasteners. 
  
 
Ceiling ducting 
If the duct will vent straight up to the ceiling: 
•   Use  level to  draw  a  line  straight  up, from the centerline 
on the template to the ceiling. 
•   Measure at least 4 -3/4 ” from the back wall to the circle 
center of an 8-½” hole on the ceiling. 
Wall ducting 
If ductwork will vent to rear: 
•   Use a level to draw a line straight up from the centerline 
on the template. 
•   Measure  at  least  23  -  3/4"  (the  measure  might  vary 
dependig  on  the  elbow  used)  above  the  pencil line  that 
indicates  the  bottom  installation  height,  to  the  circle 
center  of  an  8-½”  diameter  duct  hole  (Hole  may  be 
elongated for duct elbow). 
  
House wiring location 
•   The  junction  box  is  located  on  the  top  left  side  of  the 
hood. 
•   Wiring should enter the back wall at least 20" above the 
bottom of the installation height, and within 5-7/8" and 4-
7/8"of the left side of the centerline. 
  
 
  
  
Install framing for hood support 
 
•  If drywall is present, mark the screw hole locations. 
Remove the template. 
•  Cut away enough drywall to expose 2 vertical studs at 
the holes location indicated by the template. 
 
Install two horizontal supports at least 4" X 2" between 
two wall studs at the bottom and upper mounting holes 
installation location. 
•  The horizontal support must be flush with the room side 
of the studs. 
 
Use cleats behind both sides of the support to secure to 
wall studs. 
•  Reinstall drywall and refinish. 
IMPORTANT- Framing must be capable of supporting 
100 lbs.