Summit CLIM15 Manuale Proprietario

Pagina di 30
OPERATING INSTRUCTIONS
 
CONTROLS OF THE ICE MAKER 
Control
 
Type Condition 
Function 
Explanation 
CHECKING THE   
WATER SUPPLY
 
 
Button Press  To 
turn 
the Ice Maker on/off, 
press and hold this button 
for approximately 3 seconds. 
1. Turn off water supply. 
2. Disconnect line from the ice 
maker. 
3. Position water supply line in 
a bucket. 
4. Turn on water and make 
sure water falls into bucket. 
5. Before reconnecting the 
water supply line to the ice 
maker, make sure the 
water is turned off, then 
reconnect the water supply 
line to the ice maker. 
If unsure, please contact 
your local plumber. 
 
① 
“Water tank is full.” 
a. Unscrew the drain cap (12) 
located on the back of the 
unit and let out the water. 
(Refer to Page 5, Fig. B.) 
 
Button 
Press 
Small amount of ice 
 
Button 
Press 
Medium amount of ice 
 
Button 
Press 
Large amount of ice 
 
Indicator Light 
ON 
Small amount of ice is selected. 
FLASHING 
Water tank is full.    ① 
 
Indicator Light 
ON 
Medium amount of ice is selected. 
 
Indicator Light 
ON 
Large amount of ice is selected. 
FLASHING 
Ice bin is full of ice.  ④ 
 
Indicator Light 
ON 
Compressor is working. 
OFF 
Compressor stopped working. 
FLASHING 
Stand by condition. 
 
Indicator Light 
Flashing at the 
same time. 
Ice maker low on water.② 
 
Indicator Light 
Flashing at the 
same time. 
Sensor breakdown   ③ 
b. After draining out all the water from the outside water tank, reconnect unit to power and it will continue to run normally. 
c. 
If “Drain pump mode” is chosen, please confirm the “Pumped water outlet switch” is in the“ON” position. If it is in the 
correct position
 
but you still
 
get a WARNING ALARM after you power off the unit, please contact a service center
.
 
d. If “Manual drainage system mode” is chosen, the outside water tank will be full of water within one or two weeks 
depending on differences in ambient temperatures, please drain the water. 
“Ice maker low on water”
 
a. Check if outside water supply is functioning normally. Please see “Checking the water supply” box above. 
b. The icemaker will remove faults automatically within 30 minutes and work normally when outside water pipe is functioning. 
c. Press “
” button and turn on the unit again if icemaker does not function normally after 30 minutes; 
d. If the icemaker still shows a WARNING ALARM after the above process is repeated, contact the service center. 
③ 
“Sensor breakdown” Please contact our authorized service center. 
 
“Bucket full” alarm:
 
a. Check if the ice bucket is full. If so, remove the ice, and the alarm will stop. 
b. If the ice bucket is not full when the alarm sounds, check to see if the ice maker cover plate is stuck. Clear any obstruction and 
replace the cover. The alarm should stop. 
c. When there is an insufficient water supply, the ice maker cover plate may stick and the “bucket full” alarm will sound. Remove any 
ice from around the cover plate and check that the water supply is sufficient. The alarm should stop.