Kenyon B41598 Manuale Istruttivo
For future reference, please record the serial number of your
cook top here:
STEP #2
Check the Electrical Supply Requirements
This product must be installed in accordance with national, state and local electric codes.
The following table provides the correct voltage, amperage and frequency that must be
supplied to the cook top.
The following table provides the correct voltage, amperage and frequency that must be
supplied to the cook top.
The supply must be from an individual grounded circuit that is protected by a circuit breaker
and rated per the specifications for the various models as shown in the table above.
and rated per the specifications for the various models as shown in the table above.
2
!
Warning: If the electric power supply does not meet the
product specifications, consult with a licensed electrician
before proceeding with installation.
product specifications, consult with a licensed electrician
before proceeding with installation.
Max Connected
Required Power
Minimum
Kenyon Part #
Model #
Load
Supply Input
Wire Size
B41510
MED2
2600 Watts
120 VAC/22A/60Hz
#12 AWG
B41515
MED2TL
2400 Watts
120 VAC/20A/60Hz
#12 AWG
B41517
MED1
1200 Watts
120 VAC/10A/60Hz
#12 AWG
B41601
CAR2
2400 Watts
120 VAC/20A/60Hz
#12 AWG
B41605
CAR1
1200 Watts
120 VAC/10A/60Hz
#12 AWG
B49510
ALP2LG
2600 Watts
120 VAC/22A/60 Hz
#12 AWG
B49515
ALP2SM
2400 Watts
120 VAC/20A/60Hz
#12 AWG
B49517
ALP1
1200 Watts
120 VAC/10A/60Hz
#12 AWG