TOOLS  NEEDED  FOR  INSTALLATION
• Saber Saw or Jig Saw
• Drill
• 1  1/4" Wood Drill Bit
• Pliers
• Phillips Screwdriver
• Flat Blade Screwdriver
• Wire Stripper or Utility Knife
• Metal Snips
• Measuring Tape or Ruler
• Level
• Pencil
• Caulking Gun
• Duct Tape
PARTS  SUPPLIED  FOR  INSTALLATION
• 1 Hardware Package
• 1 Literature Package
PARTS  NEEDED  FOR  INSTALLATION
• 2 Conduit Connectors
• Power Supply Cable
• 1 Wall or Roof Cap
• All Metal Ductwork
9 Feet Straight Duct
2 - 90˚ Elbows
Wall Cap
Total System
9.0 feet
10.0 feet
0.0 feet
19.0 feet
FIGURE  2
3.0 feet
5.0 feet
12.0 feet
0.0 feet
45˚ Elbow
90˚ Elbow
90˚ Flat Elbow
Wall Cap
FIGURE  1
CALCULATE  THE  DUCTRUN  LENGTH
The ductrun should not exceed 35 equivalent feet 
if ducted with the required minimum of 6" round 
ductwork (TWO - 6" ROUND DUCTS FOR 48" 
MODEL).  Calculate the length of the ductwork 
by adding the equivalent feet in FIGURE 1 for 
each piece of duct in the system  An example 
is given in FIGURE 2.
For best results, use no more than three 90°  
elbows.  Make sure that there is a minimum of 
24" of straight duct between elbows if more 
than one is used.  Do not install two elbows 
together.  If you must elbow right away, do it 
as far away from the hood's exhaust opening 
as possible.
   WARNING
Because  of the weight  and size of the 
rangehood canopy, two or more people 
are needed to move and safely install the 
rangehood canopy.
Failure to properly lift rangehood could 
result in damage to the product or personal 
injury.
PERSONAL INJURY HAZARD
PLAN  THE  INSTALLATION
WARNING!  BEFORE MAKING ANY CUTS OR HOLES FOR INSTALLATION, 
DETERMINE WHICH VENTING METHOD WILL BE USED AND CAREFULLY 
CALCULATE ALL MEASUREMENTS.
!
CAUTION
To reduce risk of fire and to properly exhaust 
air, be sure to duct the air outside – Do not vent 
exhaust air into spaces within walls or ceilings 
or into attics, crawl spaces, or garages.
Parts supplied in range hood package:
Remove parts from packages. Check that all parts are included.
• 2 metal grease filters for 30" (76.2 cm) models
• 3 metal grease filters for 36" (91.4 cm) models
• 3 metal grease filters for 42" (106.7 cm) models
• 4 metal grease filters for 48" (121.9 cm) models
• 2 mounting brackets with adjustment screws installed
• 2 mounting bracket screws
• 4 washer head Phillips mounting screws
• Damper
• 2 dampers for 48" (121.9 cm) model.
PRODUCT DIMENSIONS
OPTIONAL FULL WIDTH DUCT COVER 
OPTIONAL TELESCOPIC CHIMNEY