NOTE: To allow sufficient water flow to the refrigerator, a 
minimum 
¹⁄₂" size copper household supply line is 
recommended.   
 
  
4. Now you are ready to connect the copper tubing to the 
shutoff valve. Use 
¹⁄₄" (6.35 mm) OD soft copper tubing to 
connect the shutoff valve and the refrigerator.
Ensure that you have the proper length needed for the 
job. Be sure both ends of the copper tubing are cut 
square.
Slip compression sleeve and compression nut onto 
copper tubing as shown. Insert end of tubing into outlet 
end squarely as far as it will go. Screw compression nut 
onto outlet end with adjustable wrench. Do not 
overtighten.
5. Place the free end of the tubing into a container or sink, and 
turn on main water supply to flush out tubing until water is 
clear. Turn off shutoff valve on the water pipe.
NOTE: Always drain the water line before making the final 
connection to the inlet of the water valve, to avoid possible 
water valve malfunction.
6. Bend the copper tubing to meet the water line inlet, which is 
located on the back of the refrigerator cabinet as shown. 
Leave a coil of copper tubing to allow the refrigerator to be 
pulled out of the cabinet or away from the wall for service.
Connect to Refrigerator
Style 1 
1. Unplug refrigerator or disconnect power.
2. Remove and discard the short, black plastic part from the 
end of the water line inlet.
3. Thread the nut onto the end of the tubing. Tighten the nut by 
hand. Then tighten it with a wrench two more turns. Do not 
overtighten.
NOTE: To avoid rattling, be sure the copper tubing does not 
touch the cabinet’s side wall or other parts inside the cabinet. 
4. Install the water supply tube clamp around the water supply 
line to reduce strain on the coupling.
5. Turn shutoff valve ON.
6. Check for leaks. Tighten any connections (including 
connections at the valve) or nuts that leak.
Style 2 
1. Unplug refrigerator or disconnect power.
2. Remove and discard the plastic part that is attached to the 
inlet of the water valve.
3. Attach the copper tube to the valve inlet using a compression 
nut and sleeve as shown. Tighten the compression nut. Do 
not overtighten.
4. Use the tube clamp on the back of the refrigerator to secure 
the tubing to the refrigerator as shown. This will help avoid 
damage to the tubing when the refrigerator is pushed back 
against the wall.
5. Turn shutoff valve ON. 
6. Check for leaks. Tighten any connections (including 
connections at the valve) or nuts that leak. 
7. On some models, the ice maker is equipped with a built-in 
water strainer. If your water conditions require a second water 
strainer, install it in the 
¹⁄₄" (6.35 mm) water line at either tube 
connection. Obtain a water strainer from your nearest 
appliance dealer.
Style 3
1. Unplug refrigerator or disconnect power.
2. Remove and discard the black nylon plug from the gray water 
tube on the rear of the refrigerator. 
3. If the gray water tube supplied with the refrigerator is not long 
enough, a 
¹⁄₄" x ¹⁄₄" (6.35 mm x 6.35 mm) coupling is needed 
in order to connect the water tubing to an existing household 
water line. Thread the provided nut onto the coupling on the 
end of the copper tubing. 
NOTE: Tighten the nut by hand. Then tighten it with a wrench 
two more turns. Do not overtighten. 
4. Turn shutoff valve ON.
5. Check for leaks. Tighten any nuts or connections (including 
connections at the valve) that leak.
A. Bulb
B. Nut
C. Copper tubing (to refrigerator)
D. Household supply line (½" minimum)
A. Compression sleeve
B. Compression nut
C. Copper tubing
A. Line to refrigerator
B. Nut (purchased)
C. Ferrule (purchased)
D. Supplied line from refrigerator
A
B
D
C
B
C
A
D
A
B
C
A. Tube clamp
B. Tube clamp screw
C. Copper tubing
D. Compression nut
E. Valve inlet
A. Refrigerator water tubing
B. Nut (provided)
C. Bulb
D. Coupling (purchased)
E. Ferrule (purchased)
F. Nut (purchased)
G. Household water line
A
C
B
D
E
A
B
C
D
E
F
G