Troubleshooting
Occasionally, a minor problem may arise, and a service call may not be necessary- use this troubleshooting guide for a
possible solution. If the unit continues to operate improperly, call an authorized service depot or Danby’s Toll Free
Number 
for assistance.
Tel: 1-800-26-
(1-800-263-2629)
1) Unit does not work.
• No power to unit.
• Power cord is unplugged.
• Wrong voltage is being used.
• Check connection of power cord 
at power source.
• Plug in unit.
• Use proper voltage.
2) Refrigerator running too 
frequently. 
• Temperature control too cold.
• Door not closed.
• Hot food inserted.
• Doors open too long/often.
• Close proximity to heat source or direct 
sunlight.
• Check/adjust settings as needed.
• Close the door securely.
• Cool food before inserting.
• Minimize door openings/duration.
• DO NOT place unit close to heat sources 
or in direct sunlight.
3) Internal temperature too 
cold. 
• Temperature set too cold. 
• Check/adjust settings as needed.
4) Internal temperature 
not cold enough. 
• No power to unit.
• Power cord is unplugged.
• Wrong voltage is being used.
• Temperature control too warm. 
• Hot food inserted.
• Doors open too long/often.
• Air flow obstruction.
• Close proximity to heat source or direct 
sunlight.
• Check connection of power cord at 
power source.
• Plug in unit.
• Use proper voltage.
• Check/adjust settings as needed.
• Cool food before inserting.
• Minimize door openings/duration.
• Allow room for air to circulate around the 
unit. 
• DO NOT place unit close to heat sources 
or in direct sunlight.
5) Freezer not cold enough. 
• Temperature control too warm.
• Door not closed.
• Hot food inserted.
• Doors open too long/often.
• Wrong voltage is being used. 
• Check/adjust settings as needed.
• Close door securely.
• Cool food before insterting.
• Minimize door openings/ duration.
• Use proper voltage.
6) Light will not work. 
• No power to unit.
• Power cord is unplugged.
• Bulb is loose/needs replacing.
• Door switch is stuck. 
• Check connection of power cord to 
power source.
• Plug in unit.
• Tighten or replace bulb.
• Check the switch for obstructions, clean 
if necessary.
PROBLEM
POSSIBLE CAUSE
SOLUTION
8