GE RAK6052 Istruzione Sull'Installazione

Pagina di 4
Installation instructions
RAK6052
for your new
Lateral duct adapter
Before you begin—Read these instructions completely and carefully.
IMPORTANT—OBSERVE ALL GOVERNING CODES AND ORDINANCES.
Note to Installer—Be sure to leave these instructions with the Consumer.
Note to Consumer—Keep these instructions with your Owner’s Manual for future reference.
Tools Needed
• Blade-type screwdriver
• Metal cutter
• Phillips head screwdriver • 5/16
″ Nut driver
• Drill and 7/32
″ bit
STEP 1
Case preparation
1. The RAK6052 lateral duct adapter is used to
modify the Zoneline (AZ22 and AZ32 series) so
that discharged air may be directed into a
secondary room. After the RAK6052 lateral duct
adapter is installed on the Zoneline chassis and
case, a 44
″ long lateral duct (RAK601) may be
attached to either the right or left end of the
RAK6052 lateral duct adapter.
Note: Minimum Clearance
          of 10
≤ recommended
          above RAK6052 for
          proper air discharge.
Ceiling
Outside
wall
1/4
≤ Min.
Air
discharge
Mounting
plate
Transition duct
Floor line
10
1
2. The RAB71 or RAB77 case should be installed in
the wall according to instructions packed with
the case, but using the following recommended
dimensions:
• Projection of case into room—1
″ min. This is
critical to allow clearance for mounting plates
and screws. If less than 1
″ of the case projects
into the room, it will be necessary to allow for
the additional width in the wall opening for 
the case.
• Projection of case to outside—1/4
″ min.
• Either side of case to adjacent wall—2
″ min.
The case must be level, not tilted towards
outside or inside. Be sure that drapes, 
window sill overhang, etc. will not interfere
with air discharge from the completed lateral
duct adapter.
• Non-obstructed wall surface above top of
lateral duct adapter—10
″ min.
Outside wall
Top of case
Min. 2
Min. 2
Adjacent wall
Parts Included
• Lateral duct adapter assembly
• Painted 5/16
″ hex head screws (4)
• Unpainted slotted screws (4)
• Mounting plates (2)
• Speed clips (4)
• Foam gaskets (2)
• Metal seal strip
Pub No. 30-7785-2   5/99 JR