Friedrich PDE15R5SF Scheda Tecnica
PTAC_SUBMITTAL_11 (2-11)
PTAC
Cooling Only, Electric Heat, Heat Pump
PURCHASER
P.O. #
DATE
PROJECT
LOCATION
ENGINEER
ARCHITECT
SUBMITTED BY
FOR APPROVAL
FOR REFERENCE
ITEM
PLAN DESIGNATION
QUANTITY
COOLING BTU/H
VOLTAGE
FRIEDRICH MODEL
PDXWS
Wall Sleeve
Qty
PDXWSEXT Deep Wall Extension
Qty
PXGA
Standard Outdoor Louver
Qty
PXAA
Architectural Louver, clear
Qty
PXBG
Architectural Louver, beige
Qty
PXSC
Architectural Louver, color matched
Qty
PDXRTA
Remote Thermostat Escutcheon Kit
Qty
PXDR10
Condensate Drain Kit (pkg/10)
Qty
PXSB
Sub Base
Qty
PXSE
T-Series Sleeve Adapter
Qty
PXCJA
Conduit Kit w/Junction Box
Qty
PDXDAA
Lateral Duct Adapter
Qty
PDXDEA
Lateral Duct Extension
Qty
PXFTA
Replacement Filters (Set of 10)
Qty
Accessories
PXSB23015
Electrical Subbase - 230V 15A
Qty
PXSB23020
Electrical Subbase - 230V 20A
Qty
PXSB23030
Electrical Subbase - 230V 30A
Qty
PXSB26515
Electrical Subbase - 265V 15A
Qty
PXSB26520
Electrical Subbase - 265V 20A
Qty
PXSB26530
Electrical Subbase - 265V 30A
Qty
PXPC23000
LCDI 230V 15A Cord, 0kw
Qty
PXPC23015
LCDI 230V 15A Cord, 2kW
Qty
PXPC23020
LCDI 230V 20A Cord, 3kW
Qty
PXPC23030
LCDI 230V 30A Cord, 5kW
Qty
PXPC26515
Non-LCDI 265V 15A Cord, 2kW
Qty
PXPC26520
Non-LCDI 265V 20A Cord, 3kW
Qty
PXPC26530
Non-LCDI 265V 30A Cord, 5kW
Qty
RT6
Digital Remote Thermostat-2 speed fan switch
Qty
Features
Constant room comfort monitoring
“Instant Heat” heat pump mode quickly
“Instant Heat” heat pump mode quickly
heats a room to the desired temperature for
increased comfort
Even heat monitoring checks room
Even heat monitoring checks room
temperature and automatically adds heat
boost if necessary
Room freeze protection- heat initiated if
Room freeze protection- heat initiated if
temperature falls to 40°F in an unoccupied
room, raising temperature to 46°F
Dual motors for quiet operation
Durable, powder coat paint finish
Indoor coil frost sensor protects the
Dual motors for quiet operation
Durable, powder coat paint finish
Indoor coil frost sensor protects the
compressor to lengthen the life of the unit.
Random compressor restart protects
Random compressor restart protects
electrical systems from overload when
power is restored
Separate heat and cool range limits
Desk control ready allowing hotel owners
Desk control ready allowing hotel owners
to control units from a central location
Electronic defrost control ensures more
run time in the efficient heat pump mode
Universal heaters with heat capacities
Electronic defrost control ensures more
run time in the efficient heat pump mode
Universal heaters with heat capacities
determined by the power cord used with
the unit
Fresh air damper control to bring in fresh
outside air when desired
Washable, antimicrobial air filter
Service error code memory storage
Emergency heat override
Washable, antimicrobial air filter
Service error code memory storage
Emergency heat override