U-Line 2275DWRC Istruzione Sull'Installazione

Pagina di 15
Door Swing Dimensions
5
The unit must be installed in a wall or under a counter-top to allow 
for the installation of the Anti-Tip Kit (see Page 14).
WARNING
The Anti-Tip Kit must be installed on this unit before it 
is used. Never use the drawers as steps or as a shelf to 
support more than the drawers’ contents. Serious 
personal injury could occur.
The unit is designed so it can be installed next to a wall on either 
side. 
The drawer unit can be installed with an appliance or fixture 
located in front of it, as long as there is adequate clearance for the 
drawer to be opened and removed when servicing.
U-Line recommends you consider additional clearance in front of 
the open drawer for convenience.
6 Clearance Information
Other Site Requirements
Power Supply
The unit requires a grounded and polarized 115 VAC, 60 Hz, 15A 
circuit (normal household current). See Electrical Specifications.
Water Supply
The unit requires a 1/4-inch OD water supply line and a shut-off 
valve. For more information see Page 12.
Environmental Requirements
The units are designed to operate between 50°F (10°C) and 100°F 
(37°C). High ambient temperatures (100°F [37°C] or higher) may 
reduce the unit’s ability to reach low temperatures and may also 
reduce the ice production rate for those models with icemakers.
If the ambient temperature is expected to drop below 45°F (7°C), 
drain all water from the unit to prevent freezing damage, which is 
not covered by the warranty.
For best performance, keep the unit out of direct sunlight and away 
from heat generating equipment.
For best performance and life outdoors, place under a counter or 
provide shelter of some kind.
In climates where high humidity and dew points are present, 
condensation may appear on outside surfaces. This is considered 
normal. The condensation will evaporate when the humidity drops.
Cabinet
or Wall
24" Min.