Dacor OBAD Istruzione Sull'Installazione

Pagina di 20

 warninG
This installation must conform to local codes or, in 
the absence of local codes, with either the National 
Fuel Gas Code, ANSI Z223.1/NFPA 54, Natural 
Gas and Propane Installation Code, CSA B149.1, or 
Propane Storage and Handling Code, B149.2.
Prevent grill combustion products from being drawn 
into a building through fresh air inlets: The venting 
system of other than a direct-vent appliance must 
terminate at least 4 feet (1.2m) below, 4 feet (1.2m) 
horizontally from, or 1 foot (305mm) above any door, 
window or gravity air inlet into any building. The 
bottom of the vent terminal must be located at least 
12 inches (305mm) above grade.
A MINIMUM clearance of 10 inches (254mm) must 
be maintained, above the countertop material, from 
all combustible vertical materials on the sides and 
behind the outdoor grill chassis and canopy. 
On all models except OBSB162, a MINIMUM 
clearance of 1 1/4 inches (32mm) must be 
maintained, above the countertop material, from all 
non-combustible vertical materials on the sides and 
behind the outdoor grill chassis and canopy. 
On model OBSB162, a MINIMUM clearance of 
2 inches (51mm) must be maintained, above the 
countertop material, from all non-combustible vertical 
materials on the sides and behind the chassis. 
A MINIMUM clearance of 1/4 inch (6mm) must be 
maintained, inside the base enclosure below the 
countertop material, from all vertical surfaces on the 
sides of the appliance, except on model OBSB162. 
On model OBSB162 a minimum clearance of 1/4 
inch (6mm) must be maintained in back and 1/16 
inch on the sides.
A MINIMUM clearance of 3/4 inch (19mm) must be 
maintained, from the bottom of the control panel to 
any material for ventilation purposes. Failure to do 
so will block air flow through the outdoor grill and 
may cause carbon monoxide poisoning or improper 
operation.
The back edge of the grill must maintain a minimum 
clearance (10 inches/254mm) from combustible back 
splash materials. Special cabinet and countertop 
dimensions are required.
The electrical outlet and gas service must be 
installed only by a qualified, licensed professionals.
The maximum gas supply pressure to the regulator 
must not exceed 1/2 pound per square inch.
Planning the Installation
Gas and Electric Power Requirements
Prior to installation, the gas supply for natural gas 
or whole house LP installations must meet the 
specifications below.
For natural gas or whole house LP installations, have a 
qualified plumber or gas fitter install a 3/4 inch (19mm) 
or 1/2 inch (13mm) gas supply line with a shut off 
valve (not included). Have it installed in an accessible 
location that allows it to be shut off when the appliance 
is installed. 
Correct voltage, frequency and amperage must be 
supplied to the appliance from an isolated, grounded 
circuit which is protected by a properly sized circuit 
breaker or time-delay fuse. The required voltage, 
frequency, and amperage ratings are listed on the 
product data plate and are also below.
It is the owner’s responsibility to ensure that the 
electrical connection to this appliance is installed by a 
qualified electrician. The electrical installation, including 
minimum supply wire size and grounding, must be 
done in accordance with National Electric Code ANSI/
NPFA 70, (or the latest revision) or Canadian Electrical 
Code CSA C22.1, and local codes and ordinances for 
connection of an outdoor appliance.
 Locate the electrical outlet within reach of the 48 Inch 
(1219mm) long power cord so that it will reach when 
the grill is completely installed in the enclosure.
Total connected loads shown include the ignition 
system, interior lights and rotisserie motor. 
The rotisserie motor should be plugged into the same 
grounded outlet power source or an alternate 120 Vac 
duplex outlet located on the same circuit as the grill.
Location Planning - General
electrical requirements
Circuit Requirement
120 Vac, 15 A
Total Connected Load
2.9 Amps, (0.35 Kw)
Gas supply requirements
Model Type
Manifold Pressure
Minimum Gas 
supply Pressure
Natural Gas
4” Water Column
5” Water Column
LP Gas
11” Water Column
12” Water Column