Dacor EG366SCHLP Guida Alla Progettazione

Pagina di 4
PLANNING
GUIDE
www.Dacor.com
Phone: (800) 793-0093
Specifications are subject to change without notice.
See installation instructions for additional details.
4.8
CAbINEt/CoUNtErtoP CUtoUt DImENsIoNs WIth rAIsED VENt - toP VIEW
CAbINEt/CoUNtErtoP CUtoUt DImENsIoNs 
WIth rAIsED VENt - sIDE VIEW
36 Inch and 48 Inch Wide
Epicure
®
 Gas Cooktops
EG366, EG486
Document # PG04 - 001
Revised 09/09/09   Page 4/4
Model No.
B - Cutout 
Width
D - Hole 
Offset
E - Raised Vent 
Cutout
EG366
36”  
(914 mm)
16 5/8”  
(422 mm)
33 1/2” 
(851 mm)
EG486
48”  
(1219 mm)
20 13/16” 
(529 mm)
43 1/2”  
(1105 mm)
Model 
No.
Approved Raised
Vent Models
EG366
ERV36, PRV36
EG486
ERV48, PRV48
Cutout tolerances: +1/16”, -0,  (+1.6 mm, -0) unless otherwise stated
Non combustible rear 
wall recommended
10” (254 mm) Min. to 
combustible wall 
above countertop, 
both sides
Cabinet face 
below countertop 
overhang
3/8” (10 mm) Min. 
countertop overhang
2 5/8”
(67 mm)
Hole 1/2” dia. (13 mm), 
2 places, through platform
for hold down bolts 
1/2” (13 mm) 
countertop 
overhang
1” thick mounting platform Min.
Open to below to allow for raised 
vent, gas and electrical connections
Countertop
Countertop
1/2” (13 mm) 
countertop 
overhang
2” (51 mm)
1” (25 mm)
11 7/16” 
(291 mm)
15”
(381 mm)
24 5/8”
(625 mm)
CL
D
D
E
B
CL
CL
CL
Stiffener
Cabinet face
Control panel
Countertop
Dacor approved
raised vent
IMPORTANT: See raised vent
installation instructions for 
duct system layout/planning 
EG366 or EG486 cooktop
3/8” Min. (10 mm)
space behind
raised vent 
chassis to clear
stiffener
3/8” Min. (10 mm)
flat countertop overhang
required behind cutout
Minimum
countertop 
height: 
30 1/4"
(768 mm)
IMPORTANT: Use only the raised vents specified.