A - 13 inches maximum depth of overhead cabinets
B - 36 inches is minimum height of countertop above floor
C - The minimum flat countertop surface that the cooktop will rest
      upon must be equal to or greater than the overall cooktop 
      dimensions (refer to the following page for overall cooktop 
      dimensions).
D - 30 inches minimum clearance between the top of the cooking
      surface and the bottom of an unprotected wood or metal cabinet or 
      24 inch minimum clearance when the bottom of the wood or metal
      cabinet is protected by not less than 1/4-inch-thick flame retardant
      millboard covered with not less than No. 28 MSG sheet steel, 
      0.015-inch-think stainless steel, 0.024-inch-thick aluminum or 
      0.020-inch-thick-copper.
E - 1-inch minimum from backsplash of countertop to edge of glass
      (refer to the following page for overall cooktop dimensions).
FOR INSTALLATIONS IN CANADA:  
“Do Not Install Closer Than 1/2 Inch 
(12mm) From Any Adjacent Surface”, and 
NE PAS INSTALLER A’MDINS DE 12MM 
DETOUTE SURFACE ADJACENTE.
Warning:  To eliminate the risk of burns by reaching over heated 
surface units, cabinet storage space located above surface units 
should be avoided.  If cabinet storage is to be provided, the risk can 
be reduced by installing a range hood that projects horizontally a 
minimum of 5” beyond the bottom of the cabinets.
!
Before making the countertop cutout, check for clearance.  Check to see if the cooktop will clear 
the front and side walls of the base cabinet.  It is also important to provide enough ventilation.
Adequate ventilation of the space below the 
countertop must be provided to ensure 
proper operation of the cooktop.  Heat 
transferred from the cooktop bottom pan 
during operation will overheat an improperly 
ventilated area.
Allow a 2” minimum clearance between the bottom of the metal pan of the cooktop and any 
combustible surface located below, ie:  the upper edge of a drawer installed below the cooktop 
(see Fig. B).  Failure to provide proper clearance and ventilation may result in a fire hazard.
7
Fig. A
2 INCH (51mm) MINIMUM
Fig. B