Sub-Zero UC24R Istruzione Sull'Installazione

Pagina di 32
subzero.com   
|
   5
SITE PREPARATION
Electrical
Installation must comply with all applicable electrical codes.
The electrical supply should be located within the shaded 
area shown in the illustration below. A separate circuit, 
servicing only this appliance is required.
IMPORTANT NOTE:
 The electrical outlet must be placed so 
the grounding prong is to the right of the thinner blades. 
The outlet must be flush with the back wall.
Model UC-24RO is designed and safe for use in outdoor 
applications. When installed outdoors, a ground fault 
circuit interrupter (GFCI) is required to reduce the risk of 
electrical shock. A GFCI is not recommended for use with 
other undercounter models and may cause interruption of 
operation.
ELECTRICAL REQUIREMENTS
Electrical Supply 
115 VAC, 60 Hz
Service
15 amp
Receptacle
3-prong grounding-type
 WARNING
Do not use an extension cord, two-prong adapter or 
remove the power cord ground prong.
Plumbing
Installation must comply with all applicable plumbing codes.
For model UC-24CI, the water supply should be located 
within the shaded area shown in the illustration below. 
The water supply line should be connected to the house 
supply with an easily accessible shut-off valve. Do not use 
self-piercing valves.
A reverse osmosis system can be used provided there is 
constant water pressure of 20–100 psi
 (1.4–6.9 bar)
 supplied 
to the unit at all times. A copper line is not recommended 
for this application.
PLUMBING REQUIREMENTS
Water Supply 
1
/
4
" OD copper, braided 
stainless steel or PEX tubing
Pressure
20–100 psi
 (1.4–6.9 bar)
Excess Line for Connection
36"
 (914)
3" 
(76)
15
1
/
2
"
(394)
2"
(51)
LEFT SIDE
OF OPENING
FLOOR
 
Electrical supply location.
 
3" 
(76)
15
1
/
2
"
(394)
2"
(51)
LEFT SIDE
OF OPENING
AREA EXTENDS 1
/
2
"
 (13)
FORWARD ON FLOOR
 
Water supply location.