For future reference, please record the serial number of your
cooktop here:                                            
STEP #2
Check the Electrical Supply Requirements
This product must be installed in accordance with national, state and local electric codes.  The 
following table provides the correct voltage, amperage and frequency that must be supplied to the 
cooktop.
  
 
The supply must be from an individual grounded circuit that is protected by a circuit breaker and 
rated per the specifications for the various models as shown in the table above.
 
 
 
 
 
Max Connected               Required Power 
             Minimum
Kenyon Part #     
Model # 
       Load 
 
       
Supply Input 
 
Wire Size
B41540  
   
Med2QTCP 
2600 Watts 
 
120VAC/22A/50/60Hz   
#12 AWG
B41549  
   
Med2QTCP 
3000 Watts 
 
208VAC/14.5A/50/60Hz  
#12 AWG
B41541  
  
Med2QTCP 
3000 Watts 
 
240VAC/12.5A/50/60Hz  
#12 AWG
B41540L              
Med2QTCL 
2600 Watts 
 
120VAC/22A/50/60Hz   
#12 AWG
B41549L 
   
Med2QTCL 
3000 Watts 
 
208VAC/14.5A/50/60Hz  
#12 AWG
B41541L 
   
Med2QTCL 
3000 Watts 
 
240VAC/12.5A/50/60Hz  
#12 AWG
B41575 & B41775 
Med2QTCTP  2400 Watts 
 
120VAC/20A/50/60Hz   
#12 AWG
B41579 & B41779 
Med2QTCTP  2400 Watts 
 
208VAC/11.5A/50/60Hz              #12AWG 
B41576 & B41776 
Med2QTCTP  2400 Watts 
 
240VAC/10A/50/60Hz   
#12 AWG 
B41575L & B41775L 
Med2QTCTL  2400 Watts 
 
120VAC/20A/50/60Hz   
#12 AWG 
B41579L & B41779L    Med2QTCTL  2400 Watts 
 
208VAC/11.5A/50/60Hz  
#12 AWG 
B41576L & B41776L 
Med2QTCTL  2400 Watts 
 
240VAC/10A/50/60Hz   
#12 AWG
STEP #3
Countertop Preparation
Please read this section prior to making cutout for cooktop.
It is important to plan ahead for installation of the cooktop, keeping the following dimensions in 
mind (please refer to Figure A).
 
   
Warning:  If the electric power supply does not meet the product 
specifications, consult with a licensed electrician before proceeding 
with installation.
!
6