Gaggenau AL400721 Volantino
210
Ventilation appliances
A I 280 120
Stainless steel
Width 120 cm
Air extraction/recirculation
Width 120 cm
Air extraction/recirculation
A I 281 120
Aluminium-lacquered
Width 120 cm
Air extraction/recirculation
Width 120 cm
Air extraction/recirculation
Necessary installation accessories
A D 280 016
A D 280 016
Exhaust air duct stainless steel, for
ceiling heights 2.27 m - 2.44 m
ceiling heights 2.27 m - 2.44 m
A D 280 026
Exhaust air duct stainless steel, for
ceiling heights 2.44 m - 2.76 m
ceiling heights 2.44 m - 2.76 m
A D 280 036
Exhaust air duct stainless steel, for
ceiling heights 2.76 m - 2.98 m
ceiling heights 2.76 m - 2.98 m
A D 281 016
Exhaust air duct aluminium-lacquered,
for ceiling heights 2.27 m - 2.44 m
for ceiling heights 2.27 m - 2.44 m
A D 281 026
Exhaust air duct aluminium-lacquered,
for ceiling heights 2.44 m - 2.76 m
for ceiling heights 2.44 m - 2.76 m
A D 281 036
Exhaust air duct aluminium-lacquered,
for ceiling heights 2.76 m - 2.98 m
for ceiling heights 2.76 m - 2.98 m
Air recirculation duct for ceiling
heigths including air flow in the duct
(order activated charcoal filter
separately)
A D 280 126
heigths including air flow in the duct
(order activated charcoal filter
separately)
A D 280 126
Recirculating air duct stainless steel
for ceiling heights 2.44 m - 2.76 m
for ceiling heights 2.44 m - 2.76 m
A D 280 136
Recirculating air duct stainless steel
for ceiling heights 2.76 m - 2.98 m
for ceiling heights 2.76 m - 2.98 m
A D 281 126
Recirculating air duct aluminium-
lacquered for ceiling heights
2.44 m - 2.76 m
lacquered for ceiling heights
2.44 m - 2.76 m
A D 281 136
Recirculating air duct aluminium-
lacquered for ceiling heights
2.76 m - 2.98 m
lacquered for ceiling heights
2.76 m - 2.98 m
A D 280 396
Ceiling collar for air ducts
Stainless steel
Stainless steel
A D 281 396
Ceiling collar for air ducts
Aluminium-lacquered
Aluminium-lacquered
Special accessories
K F 001 010
K F 001 010
Activated charcoal filter
Side duct, special ducts
made to measure. For production
reasons, aluminium-lacquered ducts
have a longer delivery time.
reasons, aluminium-lacquered ducts
have a longer delivery time.
Please enquire about price.
Installation accessories for the air
recirculation ducts you will find at the
pages 236–239 .
recirculation ducts you will find at the
pages 236–239 .
Island hood
A I 280/A I 281
– Coanda effect on both sides leads
to highly efficient extraction, even
on lowest power level
on lowest power level
– Air extraction or recirculation
system
– Dimmable Soft-Light
– Operation from both sides
Output
Performance and noise level, output
level 3/Intensive:
Air output according to DIN EN 61591.
Sound power level according to
EN 60704-3.
Sound pressure level according to
EN 60704-2-13.
level 3/Intensive:
Air output according to DIN EN 61591.
Sound power level according to
EN 60704-3.
Sound pressure level according to
EN 60704-2-13.
Appliance width 120 cm
Air extraction:
470 / 640 m³/h + Coanda effect
120 / 120 m³/h.
63 / 70 dB (A) re 1 pW.
49 / 55 dB (A) re 20 μPa.
Air recirculation:
240 / 260 m³/h + Coanda effect
80 / 80 m³/h.
68 / 75 dB (A) re 1 pW.
54 / 60 dB (A) re 20 μPa.
Air extraction:
470 / 640 m³/h + Coanda effect
120 / 120 m³/h.
63 / 70 dB (A) re 1 pW.
49 / 55 dB (A) re 20 μPa.
Air recirculation:
240 / 260 m³/h + Coanda effect
80 / 80 m³/h.
68 / 75 dB (A) re 1 pW.
54 / 60 dB (A) re 20 μPa.
Features
Control panel on both sides.
3 electronically controlled output
levels.
Intensive mode with ongoing Coanda
effect.
Interval ventilation.
Run-on function.
Grease filter saturation indicator.
Cartridge-type filter, dishwasher-safe.
Fully illuminated surface with compact
fluorescent tube 2 x 36 W and
dimmable Soft-Light.
3 electronically controlled output
levels.
Intensive mode with ongoing Coanda
effect.
Interval ventilation.
Run-on function.
Grease filter saturation indicator.
Cartridge-type filter, dishwasher-safe.
Fully illuminated surface with compact
fluorescent tube 2 x 36 W and
dimmable Soft-Light.
Planning notes
For calculating the exhaust air line go
to Rodun online at
www.gaggenau.com.
For maximum duct lengths use
Gaggenau flat rectangular ducts AD 8…
or Naber-System Compair flow. Other
flat ducts are not permitted!
When installing a ventilation hood with
air extraction mode and a chimney-
vented fireplace, the hood's power
supply line needs a suitable safety
switch.
A large drop in output and significantly
increased noise can be expected in the
air recirculation mode in the case of
ventilation hoods with a very high air
output.
Vario cooktops with intensive
production of vapours like VR/VP/VF
should be placed in the middle
beneath the cooker hood (in this case
air recirculation is not recommended).
Clearance above gas appliances min.
65 cm (more than total load gas 12 kW
min. 70 cm).
Clearance above electric appliances
min. 55 cm.
Side outlet possible no lower than
58 cm from the bottom edge of the
hood (pipe middle).
Fit the socket concealed behind
ventilation duct.
Weight 41- 45 kg.
to Rodun online at
www.gaggenau.com.
For maximum duct lengths use
Gaggenau flat rectangular ducts AD 8…
or Naber-System Compair flow. Other
flat ducts are not permitted!
When installing a ventilation hood with
air extraction mode and a chimney-
vented fireplace, the hood's power
supply line needs a suitable safety
switch.
A large drop in output and significantly
increased noise can be expected in the
air recirculation mode in the case of
ventilation hoods with a very high air
output.
Vario cooktops with intensive
production of vapours like VR/VP/VF
should be placed in the middle
beneath the cooker hood (in this case
air recirculation is not recommended).
Clearance above gas appliances min.
65 cm (more than total load gas 12 kW
min. 70 cm).
Clearance above electric appliances
min. 55 cm.
Side outlet possible no lower than
58 cm from the bottom edge of the
hood (pipe middle).
Fit the socket concealed behind
ventilation duct.
Weight 41- 45 kg.
Recommendation for stainless steel
parts to match hood that have to be
welded and polished: brushed
grain 280.
Surfaces: Stainless steel 1.4016,
ground and brushed IIIC.
Recommendation for aluminium parts
to match hood: RAL 9006 white-
aluminium or request a paint sample.
The dimensions of the air ducts refer to
a distance of 1.60 m from the floor to
the bottom edge of the hood.
Convert for other installation heights:
Worktop height + minimum clearance
+ hood with duct.
parts to match hood that have to be
welded and polished: brushed
grain 280.
Surfaces: Stainless steel 1.4016,
ground and brushed IIIC.
Recommendation for aluminium parts
to match hood: RAL 9006 white-
aluminium or request a paint sample.
The dimensions of the air ducts refer to
a distance of 1.60 m from the floor to
the bottom edge of the hood.
Convert for other installation heights:
Worktop height + minimum clearance
+ hood with duct.
Connection
Total connected load 335/335 W .
Connecting cable 1.4 m with plug.
Connecting cable 1.4 m with plug.