Cleaning the filter unit
•  Periodically inspect the filter unit (ref. A fig. 5-04) and, if necessary, clean it 
under running water (at room temperature), using a stiff brush. To remove 
the filter, grip the tabs, turn anticlockwise and lift upwards; 
•  push the centre filter (ref. A fig. 5-05) from the underside to remove it from 
the micro-filter; 
•  separate the two parts which make up the plastic centre filter by pressing 
the body of the filter in the zone shown by the arrows (ref. B fig. 5-05); 
•  remove the centre filter by lifting it upwards.
•  after cleaning, remount the filter unit, joining the two parts comprising the 
centre filter by pushing slightly until they click into place; insert the centre 
filter into the micro-filter (see fig. 5-05). Reposition the filter unit (ref. A fig. 
5-04) into its seat, turning it clockwise until it locks.
B
B
A
Fig. 5-04
Fig. 5-05
EN
33
USER INSTRUCTION
6.5
Fig. 6-06
6-06
5.5 
General warnings and recommendations 
for correct maintenance
•  Clean the filters under running water (at room temperature) using a stiff 
brush. 
•  When removing the filter, take care that there are no food residues on 
it. If any residues fall into the washing pit (ref. A fig. 5-06), they might block 
hydraulic components or foul the spray arm nozzles. 
•  It is essential to thoroughly clean the filters according to the above in-
structions: the dishwasher cannot function if the filters are clogged. 
•  Carefully replace the filters in their seats, to avoid damaging the wash 
pump.
A
Prolonged disuse
•  Run the soak program twice in succession. 
•  Unplug the power cord from the socket. 
• Leave the door slightly open in order to prevent the formation of unpleas-
ant odors inside the washing tank. 
•  Fill the rinse-aid dispenser
•  Shut off the water supply tap.