30" GAS RANGE INSTALLATION INSTRUCTIONS
For proper operation, the maximum inlet pressure to 
the regulator should be no more than 14" of water 
column pressure (3,5 kPa). The inlet pressure to the 
regulator must be at least 1" (0,25 kPa) greater than 
the regulator manifold pressure setting. Examples: 
If regulator is set for natural gas 4" (1 kPa) manifold 
pressure, inlet pressure must be at least 5" (1,2 kPa); if 
regulator has been converted for LP/Propane gas 10" 
(2,5 kPa) manifold pressure, inlet pressure must be at 
least 11" (2,7 kPa).
Leak testing of the appliance shall be conducted 
according to the manufacturer's instructions, see step 
4H.
The gas supply line should be ½" or ¾" I.D.
3
 Seal the openings
Seal any openings in the floor under the appliance or in 
the wall behind the appliance after the gas supply line 
is installed.
Recommended hole 
location for through the 
floor gas entry line.
NOTe:
The gas entry 
line hole can 
be also placed 
anywhere in 
the hatched 
area.
NOTe:
The electric 
outlet can 
be placed 
anywhere in 
the hatched 
area.
Recommended hole 
location for through the 
wall gas entry line.
figure 5a
2
 Provide an adequate gas Supply
When shipped from the factory, this unit is designed 
to operate on 4" water column (1,0 kPa) Natural gas 
manifold pressure. A convertible pressure regulator 
is connected to the range manifold and MUST be 
connected in series with the gas supply line. If LP/
Propane conversion kit has been used, follow 
instructions provided with the kit for converting the 
pressure regulator to LP/Propane use.
Care must be taken during installation of range not to 
obstruct the flow of combustion and ventilation air.