4_ Preparing to install the range
ChECKING ThE INsTAllATIoN sITE
Clearances and dimensions
To install the range, refer to the following fi gure.
For installation in CANADA, a Free-standing range is not to be installed closer than 12mm 
from any adjacent surface.
CAUTION
 
CAUTION
 This range has been designed to comply with the maximum allowable wood 
cabinet temperatures of 194°F. Make sure the wall covering, countertops and cabinets around the 
range can withstand the heat (up to 194°F) generated by the range. If not, discoloration, delamination 
or melting may occur.
A
B
36”
30”
24”
6”
25”
3”
24”
3”
A : Cabinet opening
30” For U.S.A,
30”~31” For CANADA.
B : Acceptable electrical 
outlet area
Minimum dimensions
 
IMPORTANT
 To eliminate the risk of burns or fi re caused by reaching over heated surface 
units, cabinet storage space located above the surface units should be avoided. If cabinet storage is to 
be provided, the risk can be reduced by installing a range hood that projects horizontally a minimum of 
5” beyond the bottom of the cabinets.
* 30”
30”
** 15”
*  30” minimum clearance between the top 
of the cooking surface and the bottom of 
an unprotected wood  or metal cabinet; 
or 24” minimum when the bottom of the 
wood or metal cabinet is protected by not 
less than 
1
/
4
” fl ame retardant millboard 
covered with not less than no.28 MSG 
sheet steel, 0.015” stainless steel, 0.024” 
aluminum or 0.020” copper.
**  15” minimum between the countertop and 
the adjacent cabinet bottom.