U-Line 1000 Series Frost-Free Refrigerator / Freezer - Black Cabinet with White Door Manuale Utente

Pagina di 32
USER GUIDE
 Troubleshooting 2
u-line.com
SAFETY • INSTALLATION & INTEGRATION • OPERATING INSTRUCTIONS • MAINTENANCE • SERVICE
CHECKING PRODUCT TEMPERATURE
To check the actual product temperature in the 
unit:
1. Partially fill a plastic (nonbreakable) bottle with water. 
2. Insert an accurate thermometer. 
3. Tighten the bottle cap securely.
4. Place the bottle in the desired area for 24 hours. 
5. Avoid opening the unit during the testing period. 
6. After 24 hours, check the temperature of the water. If 
required, adjust the temperature control in a small 
increment (see CONTROL OPERATION). 
Causes which affect the internal temperatures of 
the cabinet include:
• Temperature setting.
• Ambient temperature where installed.
• Installation in direct sunlight or near a heat source.
• The number of door openings and the time the door is 
open.
• The time the internal light is illuminated. (This mainly 
affects product on the top rack or shelf.)
• Obstruction of front grille or condenser.
Digital Display 
Shows 1-16 or 
99
A factory test mode may be enabled. Adjust 
the temperature to 99 and press the light icon.
Product Is 
Freezing.
Because product in contact with the rear wall 
may freeze, ensure no product is touching the 
rear wall.
Adjust the temperature to a warmer set point. 
Product Is Not 
Cold Enough.
Air temperature does not indicate product 
temperature. See CHECKING PRODUCT 
TEMPERATURE below.
Adjust the temperature to a cooler set point.
Ensure unit is not located in excessive ambient 
temperatures or in direct sunlight.
Ensure the door is closing and sealing 
properly.
Ensure the interior light has not remained on 
too long.
Ensure nothing is blocking the front grille, 
found at the bottom of the unit.
Ensure the condenser coil is clean and free of 
any dirt or lint build-up.
Problem