-40 -
5. Trouble shooting
Indoor
Outdoor
Possible Reasons
E1
/
1)Room-temperature sensor
2) Indoor PCB
E2
/
1)Heat-exchange sensor
2)Indoor PCB
F21
With the malfunction, LED1 
on the outdoor mainboard 
blinks 10 times at frequency 
of 1 Hz
1) Defrosting temperature sensor
2) Outdoor PCB
F25
With the malfunction, LED1 
on the outdoor mainboard 
blinks 13 times at frequency 
of 1 Hz
1) Exhaust temperature sensor
2) Outdoor PCB
F6
With the malfunction, LED1 
on the outdoor mainboard 
blinks once at 12 times of 1 
Hz and interval of 2 seconds 
or so.
1) Ambient  temperature sensor
2) Outdoor PCB
E7
With the malfunction, LED1 
on the outdoor mainboard 
blinks 15 times
1)The outdoor mainboard needs 
dehumidification
2)The outdoor mainboard needs 
dehumidification
3)The linking cable between the indoor and 
outdoor units is not well connected or the 
core wires are not well insulated 4)The 
indoor PCB might be broken
5)The outdoor PCB might be broken
6)The SPDU might be broken
F11
With the malfunction, LED1 
on the outdoor mainboard 
blinks17or18 times at 
frequency of 1 Hz
1) The wiring of compressor is incorrect or 
the connection is poor
2)The SPDU might be broken
3) Compressor might be damaged.
F4
With the malfunction, LED1 
on the outdoor mainboard 
blinks 8 times at frequency 
of 1 Hz
1) The cryogen may have been leaked 
during installation, or there may be leakage 
in the piping system.
2)Exhaust temperature sensor is broken
3) The outdoor mainboard is damaged and 
needs be replaced