3. Electrical control
ĉ. Scope of Application
This specification use for HSU-09/12HSA03/R2
˄DB˅frequency conversion air condition are manufactured 
by Haier air condition parent company. "Setting value" (express in parameter) in this specification 
means is a parameter that is stored in EEPROM. Refer to [EEPROM parameter table].
1. Chip pin definition
This controller adopts MOTROLA MC68HC908 AB32; Chip each pin definition as following:
1
PTC4
door switch
2
IRQ
3
RST
over-zero detection
4
PTF0/TACH2
remote control receiving
5
PTF1/TACH3
SDA
6
PTF2/TBCH2
SCL
7
PTF3/TBCH3
Buzzer
8
PTF4/TBCH0
Swing stepping motor A
9
NC
10
PTF7
Swing stepping motor D
11
PTF5/TBCH1
Swing stepping motor B
12
PTF6
Swing stepping motor C
13
PTE0/TXD
network output
14
PTE1/RXD
network output
15
PTE2/TACH0
PG feedback
16
PTE3/TACH1
PG output
17
PTE4/SS
fresh air
18
PTE5/MISO
negative ion output
19
PTE6/MOSI
self check/ decrease time
20
PTE7/SPSCK
empty
21
VSS
GND
22
VDD
VCC
23
PTG0/KBD0
ultraviolet ray A
24
PTG1/KBD1
empty
25
PTG2/KBD2
empty
26
PA0 selection panel 1
sliding stepping motor A
27
PA1 high/low drive model
sliding stepping motor B
28
PA2 large/small model
sliding stepping motor C
29
PA3 A/B code selection
sliding stepping motor D
30
PA4 panel selection 2
pushup stepping motor A
31
PA5
pushup stepping motor B