PROGRAMMING THE DISPENSER
Remove the lower splash guard assembly to access the digital programming module with LCD display.
Press the Down Arrow key to enter the programming menu.
Use the Up and Down Arrow keys to scroll through the menu screens.
Select Exit to leave the programming function and return to normal operations.
NOTE 1: Flashing menu items indicate which selection is active.
NOTE 2: Values shown below are the factory default values for English units.
NOTE 3: Values in [X - X] are the Min. and Max. for that function.
L DISPENSE RATIO
(-)  35:1  (+)
SET LF TUBE SIZE
1/8    EXIT   3/16
R DISPENSE RATIO
(-)  35:1  (+)
SET RT TUBE SIZE
1/8    EXIT   3/16
 
MENU SCREEN 
 ACTION 
   DESCRIPTION
Use the (+) or (-) buttons to 
adjust the Mix Ratio
Select tube size. Size selected 
will flash ON/OFF.
Use the (+) or (-) buttons to 
adjust the Mix Ratio
Select tube size. Size selected 
will flash ON/OFF
Enter the desired Mix Ratio for the concentrate 
used in the Left dispenser. [20:1 - 100:1]
Select  Pump  Tube  Size  to  be  used  in  the  Left 
metering pump, (see Tube Selection Chart)
Enter the desired Mix Ratio for the concentrate 
used in the Right dispenser. [20:1 - 100:1]
Select Pump Tube Size to be used in the Right 
metering pump, (see Tube Selection Chart)
LF DISP VOLUME
(-)  4.0oz  (+)
RT DISP VOLUME
(-)  4.0oz  (+)
Use  the  (+)  or  (-)  buttons 
to  adjust  the  Left  portion 
volume
Use  the  (+)  or  (-)  buttons 
to  adjust  the  Right  portion 
volume
Set  the  volume  to  be  dispensed  during  a  Left 
Portion controlled dispense to:  [0 - 640 Oz.]  or   
[0 - 18.93L]
Set the volume to be dispensed during a Right 
Portion controlled dispense to:  [0 - 640 Oz.]  or   
[0 - 18.93L]