Southbend SB1059F Manuale Utente

Pagina di 140
-22-
For Machines Mfg. Since 3/11
EVS Toolroom Lathe w/DRO
P R E P A R A T I O N
Power Supply 
Requirements
Availability
The full-load current rating is the amperage 
a machine draws at 100% of the rated output 
power. On machines with multiple motors, this is 
the amperage drawn by the largest motor or sum 
of all motors and electrical devices that might 
operate at one time during normal operations.
The full-load current is not the maximum 
amount of amps that the machine will draw. If 
the machine is overloaded, it will draw additional
amps beyond the full-load rating.
If the machine is overloaded for a sufficient 
length of time, damage, overheating, or fire may 
result—especially if connected to an undersized 
circuit. To reduce the risk of these hazards, 
avoid overloading the machine during operation 
and make sure it is connected to a power supply 
circuit that meets the requirements in the 
following section.
Full-Load Current Rating
SB1042PF Full-Load Rating ......... 18.83 Amps
SB1043PF Full-Load Rating ......... 18.83 Amps
SB1045PF Full-Load Rating ......... 18.83 Amps
SB1059F Full-Load Rating ............ 16.83 Amps
SB1060PF Full-Load Rating ......... 18.83 Amps
SB1061PF Full-Load Rating ......... 18.83 Amps
Circuit Requirements
For your own safety and protection of property, 
consult a qualified electrician if you are unsure 
about wiring practices or electrical codes in 
your area.
Note: The circuit requirements listed in this 
manual apply to a dedicated circuit—where only 
one machine will be running at a time. If this 
machine will be connected to a shared circuit 
where multiple machines will be running at 
the same time, consult a qualified electrician to 
ensure that the circuit is properly sized for safe 
operation.
A power supply circuit includes all electrical 
equipment between the main breaker box or fuse 
panel in your building and the incoming power 
connections inside the machine. This circuit must 
be safely sized to handle the full-load current 
that may be drawn from the machine for an 
extended period of time.
This machine is prewired to operate on a 440V 
power supply circuit that has a verified ground 
and meets the following requirements:
Serious injury could occur if you connect 
the machine to power before completing the 
setup process. DO NOT connect to power until 
instructed later in this manual.
Nominal Voltage ............................... 440V/480V
Cycle .............................................................60  Hz
Phase ....................................................... 3-Phase
Circuit Rating....................................... 30 Amps
Connection .. Hardwire with Locking Switch
Before installing the machine, consider the 
availability and proximity of the required power 
supply circuit. If an existing circuit does not meet 
the requirements for this machine, a new circuit 
must be installed.
To minimize the risk of electrocution, fire, 
or equipment damage, installation work and 
electrical wiring must be done by an electrician 
or qualified service personnel in accordance with 
all applicable codes.