Chapter 5 - Monitoring and Testing the Campus System
Campus-REX2 RS Interface Card User Manual
89
R
ESETTING
 
THE
 C
AMPUS
 U
NIT
You can issue a reset for the Campus unit which causes it to complete a soft 
reboot. Use this function when one of the following occurs:
The Port LED flashes green and the 
REX2 Module Not Read
y message 
is displayed when trying to access the REX2 interface. This indicates that 
the Campus desktop or line unit is not communicating with the REX2 
card for more than 1 minute after power-up was indicated.
HDSL, REX2, or system configuration changes have been made, but not 
saved, and you want to revert to the previously saved configuration.
The REX2 is not functioning properly as indicated by excessive LAN 
errors or 
Not available
 displayed for configuration values.
During the reset, the Port and HDSL LEDs on the desktop unit flash.
It is not required that you reset the REX2 after a configuration change or 
when you complete a save function.
1
From the Main Menu, type 
then press 
.
4
ENTER
Jul 07, 2003 
ADC TELECOMMUNICATIONS, CAMPUS RS, Version 5.1 08:19:34
Local Unit ID:
Southall Quad 4
Local I/F:
REX2
Remote Unit ID: Inactive
Remote I/F: Inactive
Circuit ID:
Southeast line 421
MAIN MENU
1)
SYSTEM STATUS
2)
REX2 CONFIGURATION AND STATUS
3)
SYSTEM CONFIGURATION
4)
MAINTENANCE
5)
REMOTE LOGON
(L)ogout
ENTER CHOICE>