ADC Campus-REX2 RS Manuale Utente

Pagina di 166
 
Chapter 4 - Managing System Parameters
Campus-REX2 RS Interface Card User Manual
67
S
ETTING
 
THE
 T
IME
 
AND
 D
ATE
The time and date parameters provide a common time and date stamp 
for system functions such as alarm indications or performance monitoring 
histories.
1
To set the time, type 
then press 
.
2
At the prompt, type the time in a 24-hour format as shown below then 
press .
ENTER NEW TIME (FORMAT HH:MM:SS): 
16:34:09
The system displays this new time on System Parameters screen.
3
To set the date, type 
then press 
4
At the prompt, type two numbers for the day, two number for the month, 
and the four-digit year, separated by slashes (/), then press 
.
ENTER NEW DATE (FORMAT MM/DD/YYYY):
04/30/2003
The system displays this new date on System Parameters screen as 
Apr 30, 2003.
System and date take effect immediately after the values are entered and a 
save command is not required. 
I
DENTIFYING
 
THE
 U
NIT
 
AND
 C
IRCUIT
A Campus system supports two different identifiers:
The Unit ID indicates an individual Campus unit which can be either a 
desktop unit with an interface card or each interface card and line card 
combination in a Campus-Star chassis.
The Circuit ID identifies the HDSL circuit between local and remote 
units and is the same for both.
Do the following to set or change these identifiers.
1
From the System Parameters menu, type 
then press 
. At the 
prompt, enter the Unit ID using a unique identifier up to 32 characters.
Maximum length is 32 characters.
ENTER NEW UNIT ID: Southall Quad 4
1
ENTER
ENTER
2
ENTER
ENTER
3
ENTER