SPECIFICATIONS - Model Cascade 
 
Page 22 
Flue 
Size 
  3” 
Rear 
 
Width, Overall   
 
24” / 610mm 
 
Depth, Overall Stove 
 
22 1/8” / 562mm 
Depth, w/3” Tee  
 
28 ¼” / 718mm 
 
 
Height, Overall   
 
28 1/4” / 724mm 
Height (Floor to Stove Top) 
27 1/2” / 699mm 
 
Floor to Rear  
Flue Center 
 
 
14” / 356mm 
 
Facing Back of Unit, 
Left Side to Center of Rear 
Flue Outlet 
 
 
6 3/4” / 172mm 
 
Floor to Rear 
Outside Air Inlet  
 
11” / 279mm 
 
Facing Back of Unit 
Right Side to Center 
of Air Inlet 
 
 
5” / 127mm 
 
Floor Protection  
+  Front, Sides & Back = 6” 
Requirements  
 
Hopper Capacity 
 
60 lbs. 
 
Burn time 
♦  17-40 hours  
 
Fuse, Control Board 
 
8 Amp,  250 Volt* 
 
Heat Input (Max.) 
♦   12,600-30,000 BTU / hr 
Overall Efficiency 
 
Up to 81% 
 
Emissions 
♦   1.3 gram / hr (varies w/ 
size and type of fuel) 
EPA exempt 
 
Ship Weight 
 
165 lbs. 
 
Convection Blower 
 
102 CFM; 2.10 Amps, 
(Room Air Blower) 
 
2200 RPM 
 
Auger Motor  
 
1 RPM; .4 Amps 
 
Combustion Blower 
 
56 CFM; 2.10 Amps, 
(Draft Inducer) 
 
2200 RPM 
BACK VIEW 
 
 
 
SIDE VIEW 
 
 
 
 
 
Note: Dimensions shown are approximations only 
(+/- ¼”) 
 
Non-combustible thermal rated floor protection must 
be used when installed on carpet (see Floor Protec-
tion
, page 5). When installed at clearances less 
than 6”, the floor protector is only required to ex-
tend to the wall. 
 
  Fuel delivery and burn times will vary depending 
on size and type of fuel used. Estimated heat in-
put based on fuel value of 8400 BTU per lb. 
 
*  Fuses are rated as “fast blow.” 
To Stove 
Top 
Overall  
Height