Panasonic AJ-SD930BP Manuale Utente

Pagina di 80
39
Setup menus
The underlined items indicates the initial setting.
USER menu
<INTERFACE>
No./Item
Description
200
PARA RUN
This selects whether two or more VTRs are to
be operated in synchronization.
0000
DIS : No operation in synchronization
0001
ENA : Operation in synchronization
<Note>
When operating two or more VTRs in
synchronization, set all the VTRs to ENA.
202
ID SEL
This sets the ID information to be returned to
the controller.
0000
OTHER
0001 DVCPRO
0002
ORIG
<Notes>
O
ID information of any VTR except for the
DVCPRO’s is set in OTHER.
O
The ORIG setting should only be used when a
Panasonic controller (AG-A850 etc. sold
separately) is connected.
203
25P SEL
This selects whether the PARALLEL (25P)
connector functions when the CONTROL
switch has been set to REMOTE.
0000
OFF : Connector does not function.
0001
ON : Connector 71770 0 72.29ET0.5 w0 72.29 400.82 m300.76 400.82 lSBT/2 l6838 0 0 5 59.811 392.242BAUD RATE03
25P ese Tc-0.0 whethatio