Nilfisk-Advance America SR 5110 P/B Manuale Utente

Pagina di 30
S31NUK5120(3)2001-04
Warning: the following operations must be done 
with the machine in Off condition and master key 
out, on a flat floor.
When the side brush is worn its height must be 
adjusted.
Loosen the knob. Turn the adjusting disk and 
move its position of one hole. 
And tighten the knob.
To check the adjustment of the brush start it and 
verify that the contact with the floor is as shown 
in the figure. If necessary repeat the adjustment 
sequence.
When the brush is remarkably worn out, it is 
necessary to replace it. Just press the two tabs 
inwards and remove the brush. Reinstall the new 
brush by carrying out the reverse operation; 
apply a light pressure to the brush with your 
hands.
Note: when the brush is replaced set the 
adjusting devices to their original position 
(corresponding to brush new, with no 
wear).
SIDE BRUSHES ADJUSTMENT AND 
REPLACEMENT
14