MELSOFT
11. POSITIONING DEBUGGING 
 
11.1 Monitor 
Monitor the positioning data and start block data execution states on an axis basis or 
perform extended monitor of the error histories, signal states, current values, speeds, 
etc. of all axes. 
 
11.1.1 Monitoring the positioning data/start block data 
PURPOSE
 
 
From the screen of the positioning data/start block data of any axis, monitor the 
positioning data No.s or block No.s and point No.s being executed, and further 
monitor the operating status indicators such as the feed addresses, feed speeds, 
error/warning codes and M codes. 
 
BASIC OPERATION
 
 
1. Choose the positioning or start block data to be monitored. 
Double-click any of the items.
Doble-click.
 
2. Click the [Online] 
→ [Monitor] → [Monitor start] menu ( 
 ). 
 
3. Choose "Data Up-loading" (read from AD75) or "Data Down-loading" (write to 
AD75) in the monitor mode start confirmation dialog box. 
4. Click the "Extended" button and set the required data and range in the Write or 
Read dialog box. 
5. Click the "OK" button in the monitor mode start confirmation dialog box. 
6. To exit, click the [Online] 
→ [Monitor] → [Monitor start] menu ( 
 ). 
 
 