Mitsubishi Electronics A1SD75M1/M2/M3 Manuale Utente

Pagina di 212
 
 
 
Appendix - 6                                                                                                                                    Appendix - 6 
MELSOFT
APPENDICES 
 
Appendix 2.4 Comparison of GX Configurator-AP Versions 
The following table indicates the comparison of functions between the GX 
Configurator-AP versions. 
(The version can be confirmed using Product information in "Section 12.11 Help".) 
 
Version 
Item 
"1.18U" or 
later 
"1.12N" or 
later 
"1.11M" or 
later 
"1.10L" or 
later 
"07H" or 
earlier 
Compatibility with "Microsoft
R
 Windows
R
 2000 Professional 
Operating System" and " Microsoft
R
 Windows
R
 Millennium Edition 
Operating System" 
Available Available Available Available 
Not 
available 
Function to select whether "AD75P initialization" will be executed or 
not in execution of "AD75P Checking Connect" 
Available Available Available Available 
Not 
available 
Function to set "7: Near-point dog method 2 )" or "8: Count method 3 
)" in the OPR Basic Parameter "OPR method" when "AD75M# 
(A1SD75M#)" is selected for "Change AD75 model" 
Available Available Available 
Not 
available 
Not 
available 
Compatibility with "Microsoft
R
 Windows
R
 XP Professional Operating 
System" and "Microsoft
R
 Windows
R
 XP Home Edition Operating 
System" 
Available Available 
Not 
available 
Not 
available 
Not 
available 
Addition of "Absolute position restoration selection" to "OPR Extended 
parameter" when "AD75M# (A1SD75M#)" is selected for "Change 
AD75 model" 
Available Available 
Not 
available 
Not 
available 
Not 
available 
Compatibility with "Microsoft
R
Windows Vista
R
 Home Basic  
Operating System" and "Microsoft
R
Windows Vista
R
 Home Premium 
Operating System" and "Microsoft
R
Windows Vista
R
 Business  
Operating System" and "Microsoft
R
Windows Vista
R
 Ultimate  
Operating System" and "Microsoft
R
Windows Vista
R
 Enterprise 
Operating System" 
Available 
Not 
available 
Not 
available 
Not 
available 
Not 
available 
 
 
 
APPENDIX 3 REFERENCE PROCESSING TIME FOR READ FROM/WRITE TO AD75 
The processing times listed below assume that read from/write to AD75 was performed 
under the following conditions. 
 
• Peripheral device specifications 
 
Item Description 
CPU Pentium
R
 200MHz 
System software 
Microsoft
R
 Windows
R
 95 Operating System 
Main memory capacity 
48MB 
 
Read/Write Range 
 
 
Operation 
Axis #1/#2/#3 Positioning Data No. 1 to 600 
Axis #1/#2/#3 Start Block Data 
(Block No. 0 to 10) 
Axis #1/#2/#3 Parameters 
Axis #1 Positioning Data No. 1 to 600 
Axis #1 Start Block Data 
(Block No. 0 to 10) 
Axis #1 Parameters 
Read from AD75 
(AD75 
→ personal computer) 
1 minute 2 seconds 
Approx. 21 seconds 
Write to AD75 
(Personal computer 
→ AD75) 
1 minute 11 seconds 
Approx. 30 seconds 