Q-Logic 2400 Manuale Utente

Pagina di 366
10–Converged Network Adapter Interactive Commands
Loopback Test
SN0054667-00  C
10-115
Display Test Parameters
6. Loopback Test<port selection>2. FCoE1. Display Test Parameters
From the Loopback Test menu, select the Display Test Parameters option to 
view the loopback test parameters. For example:
------------------------------------------------------------------------------
HBA Instance 0: QLE8242 Port 1 WWPN 21-00-00-0E-1E-04-95-EB PortID 11-00-20
------------------------------------------------------------------------------
--------------------
Diagnostics Settings
--------------------
Data Pattern             : Random
Data Size (Bytes)        : 8
Number of tests (1-65535): 10000
Test Increment(1-65535)  : 1
Abort On Error           : Ignore
Test Continuous          : OFF
Loopback Type            : Special Echo FCoE Loopback (252) in size
------------------------------------------------------------------------
Reset Test Parameters
6. Loopback Test<port selection>2. FCoE2. Reset Test Parameters
From the Loopback Test menu, select the Reset Test Parameters option to reset 
the loopback test parameters to their default values
 lists the default 
loopback test values.
Table 10-1. Default Loopback Test Parameter Values
Parameter
Default Value
Data Pattern
Random
Data Size (Bytes)
8
Number of tests
10,000
Test Increment
1
Abort On Error
Ignore
Test Continuous
OFF
Loopback Type
Special Echo FCoE Loopback (252) in size