3com WX1200 3CRWX120695A Manuale Utente

Pagina di 750
set radius
583
MSS encrypts the display form of the string in display config and 
display aaa output.
„
retransmit number
 — Number of transmission attempts the WX 
switch makes before declaring an unresponsive RADIUS server 
unavailable. You can specify from 1 to 100 retries.
„
timeout seconds
 — Number of seconds the WX switch waits for the 
RADIUS server to respond before retransmitting. You can specify from 
1 to 65,535.
Defaults — Global RADIUS parameters have the following default 
values:
„
deadtime — 0 (zero) minutes (The WX switch does not designate 
unresponsive RADIUS servers as unavailable.)
„
encrypted-key—No key
„
key — No key
„
retransmit — 3 (the total number of attempts, including the first 
attempt)
„
timeout — 5 seconds
Access — Enabled.
History —Introduced in MSS Version 3.0. The encrypted-key option 
was added in Version 4.2.
Usage — You can specify only one parameter per command line. 
Examples — The following commands sets the dead time to 5 minutes, 
the RADIUS key to goody, the number of retransmissions to 1, and the 
timeout to 21 seconds on all RADIUS servers connected to the WX 
switch:
WX1200# set radius deadtime 5
success: change accepted.
WX1200# set radius key goody
success: change accepted.
WX1200# set radius retransmit 1
success: change accepted.
WX1200# set radius timeout 21
success: change accepted.