Desa CGDV32pR Manuale Utente

Pagina di 44
www.desatech.com
116646-01D
31
ClEaNING aND 
MaINTENaNCE
Continued
Use only the tempered glass door replacement 
intended for this fireplace (see Replacement Parts
page 36 for detail on ordering). No substitutions 
may be made. See Removing/Replacing Glass Door
page 23 for instructions for replacing glass door.
  WARNING:  Do  not  operate 
fireplace  with  the  glass  door 
unlatched,  removed,  cracked 
or broken.
pILOT AND bURNERS
•  Remove ember material before cleaning burners 
and replace when cleaning is complete.
•  Burner and controls should be cleaned with 
compressed air to remove dust, dirt or lint.
•  Use a vacuum cleaner or small, soft bristled 
brush to remove excess dust, dirt or lint.
LOGS
•  If you remove logs for cleaning, refer to In-
stalling Logs, Lava Rock and Glowing Embers
page 23, to properly replace logs.
•  Use a vacuum cleaner to remove any carbon 
buildup on logs.
•  Replace log(s) if broken. See Replacement 
Parts on page 36.
•  Replace ember material periodically as needed. 
See Replacement Parts on page 36.
vENTING SYSTEM
Conduct annual inspection of the venting system 
following these guidelines:
1.  Check areas of venting system that are exposed to 
the weather for corrosion (rust spots or streaks and, 
in extreme cases, holes). Have these items replaced 
immediately by a qualified service person.
2.  Remove the vent cap and shine a flashlight 
into the vent. Remove any foreign material.
3.  Check for evidence of excessive condensation. 
Continuous condensation can cause corrosion 
of caps, pipes and fittings and can be caused 
by having excessive lateral runs, too many 
elbows or exterior portions of the system being 
exposed to cold weather.
4.  Inspect joints to verify that no pipe section or 
fitting has been disturbed and loosened. Check 
mechanical supports such as wall straps for 
rigidity.