OPERATING FIREPLACE (REMOTE-READY MODELS)
For Your Safety Read Before Lighting
Lighting Instructions
OPERATING FIREPLACE
Continued
 WARNING: If you do not follow these instructions
exactly, a fire or explosion may result causing prop-
erty damage, personal injury or loss of life.
A. This appliance has a pilot which must be lighted by hand.
When lighting the pilot, follow these instructions exactly.
B. BEFORE LIGHTING smell all around the appliance area
for gas. Be sure to smell next to the floor because some gas
is heavier than air and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electric switch; do not use any phone in
your building.
• Immediately call your gas supplier from a neighbor’s
phone. Follow the gas supplier’s instructions.
• If you cannot reach your gas supplier, call the fire
department.
C. Use only your hand to push in or turn the gas control knob.
Never use tools. If the knob will not push in or turn by
hand, don’t try to repair it, call a qualified service techni-
cian or gas supplier. Force or attempted repair may result
in a fire or explosion.
D. Do not use this appliance if any part has been under water.
Immediately call a qualified service technician to inspect
the appliance and to replace any part of the control system
and any gas control which has been under water.
FOR YOUR SAFETY
READ BEFORE LIGHTING
REMOTE-READY MODELS
1.
STOP! Read the safety information above.
2.
Make sure equipment shutoff valve is fully open.
 WARNING: Burner will come on automatically
within one minute when control valve is in the ON
position after the pilot is lit.
LIGHTING
INSTRUCTIONS
 WARNING: You must operate this fireplace with
the fireplace screen in place. Make sure fireplace
screen is installed before running fireplace.
NOTICE: During initial operation of new fireplace,
burning logs will give off a paper-burning smell. Open
window to vent smell. This will only last a few hours.
Figure 39 - Control Knob and Ignitor Button Location (Shown as
Supplied - No Control Options)
HI
LO
IN
OUT
Piezo Ignitor
Button
Control Knob
Flame
Adjustment
Knob
 CAUTION: Do not try to adjust heating levels by
using the equipment shutoff valve.
Figure 40 - Propane/LP Gas Pilot
Ignitor
Electrode
Pilot
Burner
Figure 41 - Natural Gas Pilot
Ignitor
Electrode
Pilot
Burner
3.
Press in and turn control knob clockwise  
 to the
OFF position (see Figure 39).
4.
Wait five (5) minutes to clear out any gas. Then smell for
gas, including near the floor. If you smell gas, STOP! Fol-
low “B” in the safety information, column 1. If you don’t
smell gas, go to the next step.
5.
Press in and turn control knob counterclockwise 
to the PILOT position. Press in control knob for five (5)
seconds (see Figure 39).
Note:
 You may be running this fireplace for the first time
after hooking up to gas supply. If so, the control knob may
need to be pressed in for 30 seconds or more. This will al-
low air to bleed from the gas system.
6.
With control knob pressed in, press and release ignitor but-
ton. This will light pilot. The pilot is attached to the front
burner. If needed, keep pressing ignitor button until pilot lights.
Note:
 If pilot does not stay lit, contact a qualified service
person or gas supplier for repairs. Until repairs are made,
light pilot with match. To light pilot with match, see Manual
Lighting Procedure, 
page 22.
7.
Keep control knob pressed in for 30 seconds after lighting
pilot. After 30 seconds, release control knob.
• If control knob does not pop out when released, contact
a qualified service person or gas supplier for repairs.
Note:
 If pilot goes out, repeat steps 4 through 8.
8.
Slightly push in and turn control knob counterclockwise
 to the ON position.
9.
Set flame adjustment knob to any level between HI and LO.