10
1.14 A-Scope Display
This display shows echoes at each transmission 
with amplitudes and tone proportional to their 
intensities, on the right of the screen. It is useful 
for estimating the kind of fish school and bottom 
composition.
Note: In the dual frequency display, the A-
Scope display is only available with the high fre-
quency display.
1. Press the MENU/ESC key to open the menu.
2. Use 
S
 or 
T
 to choose Display and press the 
ENTER key.
Display menu
3. Use 
S
 or 
T
 to choose A-Scope and press 
the ENTER key.
A-Scope setting box
4. Use 
S
 or 
T
 to choose the A-Scope presen-
tation type desired and press the ENTER 
key.
Normal: Display shows echoes at each 
transmission with amplitudes and tone pro-
portional to their intensities.
Peak: “Normal” A-Scope display plus peak-
hold amplitude picture for last five seconds in 
dots.
5. Press the MENU/ESC key twice to close the 
window.
A-Scope display
Note: To turn off the A-Scope display, choose 
Off at step 4 and then press the ENTER key.
1.15 Fish Information
You can turn the fish symbol indication (Solid or 
Striped) on or off. Also, you can show or hide 
the fish level and the depth value. For details 
about the Fish Symbols, see the information 
which follows the procedures in this section.
Note: The fish level found by this sounder is 
intended for reference purposes; it is not an 
accurate measurement of fish length.
Fish Symbols
1. Press the MENU/ESC key to open the menu.
2. Use 
S
 or 
T
 to choose Display and press the 
ENTER key.
3. Use 
S
 or 
T
 to choose Fish Symbols and 
press the ENTER key.
Fish Symbols setting box
4. Use 
S
 or 
T
 to choose Solid or Striped and 
press the ENTER key.
The level of fish symbol depends on the fish 
size.
(   ): Level range for meter unit
[   ]: Level range for feet unit
 Display
S
 / 
T
 / 
W
 / 
X
  :  Select
[ENTER]             :  Enter
[MENU]                     :  Back
A-Scope            : Off
Depth Size       : Small
Zoom Marker   : Off
Temp Graph    : Off
Window Size
Battery             : Off
Color Bar         : On
Palette             : White
Colors              : 64 
Header Info      : On
Nav Data1        :
Nav Data2        :
Fish Info           : Off
Fish Symbols   : Off
Sounder
Display
Alarm
Data
   System
Menu
T
Off
Normal
Peak
Symbol size, level
Solid
Striped
Large fish symbol
(more than 50), 
[more than 20]
Small fish symbol
(10 to 49), [4 to 19]
1/1
50k
W
G:AF R:A
20
40
60
80
0
59.8
m
0.0
Single
frequency
display
A-Scope display 
Weak echo
(small fish
  school or 
  noise)
School fish
Strong echo
(bottom)
Past amplitude
pictures are
displayed with
dots with Peak
mode.
Off
Solid