Furuno 1622 Manuale Utente

Pagina di 24
 
 
12
2.  Turn on the power. Do not transmit the 
radar. 
3.  Connect a multimeter, set to 10 V DC 
range, between #6(+) and #4(-) of test 
point TP804 on the MD Board in the 
antenna unit. 
4.  Confirm that the multimeter shows 8.0 V 
±0.1 V. If it does not, adjust potentiometer 
VR801 on the MD Board. 
TP804
VR851
VR801
 
Figure 27 Antenna unit, inside view 
 
2) Radar function 
This radar can function as the main radar or a 
demonstration model. displaying internally 
generated radar echoes. 
1.  Set the radar in stand-by. 
2.  Press and hold down ▲ and ▼ together 
(about 10 seconds) to display the 
maintenance menu. 
     NAV DATA (NMEA 0183)
GLL
BWR
BWC
GLC
GTD
RMA
RMG
RMC
VTG
MTW
DBT
DBS
DPT
GGA 
PROGRAM NO
03591610XX
SEL MENU
BY KEY
         
MAIN
      DEMO
  ▲
/
MODEL      
M1622
    M1621/M2
DISPLAY
1
2
 
Figure 28 Maintenance menu 
3.  Select MAIN or DEMO from the DISPLAY 
field. (MAIN, Main radar display, DEMO, 
demonstration display.) 
4.  Press the [MENU] to close the menu. 
3.5 I/O Data Confirmation 
You can confirm NMEA input from a navigator 
or echosounder. Follow the procedure shown in 
2) Radar function to display the maintenance 
menu. NMEA sentences being input are shown 
in reverse video. 
3.6 Restoring Default   
  
Settings 
All default menu settings can be restored by 
turning on the power while pressing and holding 
down [MENU] and 
&
.
Note: Disconnect the antenna cable to use 
as demonstration model.