MERLIN LEGENDCommunications System Release 6.1
System Planning  
555-661-112  
Issue 1
August 1998
Unit Load Calculation 
Page F-3
Unit Load Worksheet 
F
Unit Load Worksheet
F
1.
Number of modules in carrier (excluding power supply 
and processor):
__________________
If fewer than 5, no further calculation is required.
If 5 or 6, continue to Step 2.
2.
Key or Behind Switch mode only: 
Indicate the configuration of lines; then go to Step 5.
 

 Key
 

 Modified
3.
Hybrid/PBX mode only: 
Do all modules in the carrier have MLX and/or 
analog multiline telephone jacks?
If no, no further calculation is required.
If yes, continue to Step 4.
 

 Yes 
 

 No 
4.
Hybrid/PBX mode only:
Calculate the total number of MLX and analog 
multiline telephones.
Number of MLX-20L telephones connected to 
modules in the carrier:
__________________
Number of MLX-28D telephones connected to 
modules in the carrier:
__________________
Number of 34-button analog multiline telephones 
connected to modules in the carrier:
__________________
Total of MLX-20L, MLX-28D, and 34-button analog 
telephones
__________________
If the total is less than 45, no further calculation is 
required.
If the total is 45 or more, continue to Step 5.