Lucent Technologies 6.1 Manuale Utente

Pagina di 588
MERLIN LEGENDCommunications System Release 6.1
System Planning  
555-661-112  
Issue 1
August 1998
Before You Begin 
Page 1-9
Requirements for Supporting CTI Applications 
1
For a NetWare 3.12 installation, ensure that NWSNUT.NLM, Version 4.11 
or later, and TUI.NLM, Version 1.04 or later, is obtained from Novell and 
installed in the SYS:\SYSTEM directory.
NOTE:
To obtain these NLMs from Novell, access either the Novell web site 
(http:\\www.novell.com) or the Novell FTP site (ftp.novell.com). First 
download IPXRT4.EXE and follow the directions in the associated 
readme file. Then, download NWSNUT.NLM and TUI.NLM.
For a Windows NT installation, the required .DLLs and drivers will be 
provided on a CD-ROM.
For more information on setting up the system see the MERLIN LEGEND 
Communications System 
Network Manager’s Guide.
Environmental Specifications
1
If the Telephony Server platform and the MERLIN LEGEND Communications 
System are to share an equipment room, the room’s environment (temperature, 
humidity, contaminants, EMI, AC power and grounding) must meet the more 
demanding set of environmental specifications for the two units. Refer to the 
specifications for each hardware platform for details.